期刊文献+

均衡电抗器及变压器漏感在12脉波整流系统中的影响分析 被引量:1

Analysis of influence of equilibrium reactor and transformer leakage inductance in 12 pulse rectifier system
下载PDF
导出
摘要 以船用推进为背景,对一种带直流均衡电抗器的12脉波整流系统网侧谐波电流表达式进行了推导及简化。综合考虑了变压器交流输入端漏感、整流输出端均衡电抗器、变频器直流输入电压等因素,对其与电网电流总谐波畸变及输入功率因数的关系进行了分析和仿真,仿真与试验表明:计算与实际情况具有较高的吻合度。该方法尤其适用于对系统参数匹配性敏感的特殊船舶应用领域。 An expression of line-side harmonic current for 12 pulse rectifier system with DC equilibri- um reactor is deduced and simplified on the background of ship propulsion. The relationships of the total harmonic distortion of the grid current and the input power factor are analyzed and simulated with the consideration of such factors as leakage inductance of transformer AC input, equilibrium reactor of rectifier output, inverter DC input voltage, etc. The simulation and experiment results show that the compute results agree well with the actual situation. This method is particularly suitable for special marine applications which are sensitive to system parameters matching.
出处 《海军工程大学学报》 CAS 北大核心 2017年第1期12-17,共6页 Journal of Naval University of Engineering
基金 国家自然科学基金资助项目(51490681) 国家973计划资助项目(2015CB251004)
关键词 电力推进 整流 漏感 均衡电抗器 谐波 electric propulsion rectifier leakage inductances' equilibrium reactor harmonics
  • 相关文献

参考文献9

二级参考文献98

  • 1高格,傅鹏.可控并联十二脉波四象限运行整流电源的研制[J].电工技术学报,2004,19(7):16-20. 被引量:19
  • 2陈鹏,李晓帆,宫力,熊招春.一种带辅助电路的12脉波整流电路[J].中国电机工程学报,2006,26(23):163-166. 被引量:33
  • 3周丽霞,尹忠东,肖湘宁.基于移相电抗器的电力推进船舶电网谐波抑制[J].电工技术学报,2007,22(8):90-94. 被引量:15
  • 4YANG Shiyan,MENG Fangang,YANG Wei. Optimum design of inter-phase reactor with double-tap-changer applied to multi- pulse diode rectifier[J]. IEEE Trans on Industrial Electronics, 2010,57(9) :3022-3029.
  • 5MENG Fangang,YANG Shiyan,YANG Wei. Comments and further results on "a new critical formula and mathematical model of double-tap interphase reactor in a six-phase tap- changer diode rectifier" [J]. IEEE Trans on Industrial Electronics, 201 O, 57 (3) : 950-953.
  • 6PAN Qijun,MA Weiming,LIU Dezhi,et al. A new critical formula and mathematical model of double-tap interpbase reactor in a six-phase tap-changer diode rectifier[J]. IEEE Trans on Industry Electronics, 2007,54 ( 1 ) : 479-485.
  • 7DOMINGUES E G,OLIVEIRA J C,DELAIBA A C,et al. Three-phase timing domain modeling of special transformers in the SABER simulator[C]//IEEE 8th International Conference on Harmonics and Quality of Power. Athens,Greece:IEEE, 1998 : 1047-1052.
  • 8CHOI S,LEE B S,ENJETI P. New 24-pulse diode rectifier systems for utility interface of high power AC motor drives[J~. IEEE Trans on Industry Applications, 1997,33(2) :531-541.
  • 9TANAKA T,KOSHIO N,AKAGI H,et al. Reducing supply current harmonics[J]. IEEE Industry Applications Magazine, 1998,4(5) :31-37.
  • 10SCHLABACH L. Analysis of discontinuous current in a 12- pulse thyristor DC motor drive [J]. IEEE Trans on Industry Applications, 1991,27 (6) : 1048-1054.