期刊文献+

干熄焦锅炉过热器失效机理分析及防漏实践 被引量:1

Failure Mechanism Analysis and Leak Proof Practice for Superheater of CDQ Boiler
下载PDF
导出
摘要 干熄焦余热锅炉承压部件的安全运行对整个干熄焦的安全生产至关重要。过热器位于余热锅炉入口部位,最先受到高温循环气体的冲刷、磨损,是最容易发生泄漏的部位。文章结合包钢干熄焦实际,分析了过热器爆管泄漏的机理、原因及实际采取的一些对策,以求对锅炉过热器设备的完好运行有所裨益。 The safe operation for pressure-bearing parts of waste heat recovery boiler is essential to the safe production of CDQ.Located in the waste heat boiler inlet,superheater is the most prone to leakage since it is the first to be eroded and worn by the high temperature recycle gas.In this paper,combined with the actual production of CDQ in Baotou Steel,analyzed the mechanism,reasons and practical measures of superheater tube burst to facilitate the superheater equipment to run well.
出处 《包钢科技》 2017年第1期5-7,22,共4页 Science & Technology of Baotou Steel
关键词 干熄焦 余热锅炉 过热器 爆管 CDQ waste heat recovery boiler superheater tube burst
  • 相关文献

参考文献1

二级参考文献2

  • 1陶曾毅.电厂金属材料[M].武汉:华中理工大学出版社,1994..
  • 2范从振.锅炉原理[M].北京:水利电力出版社,1995..

共引文献3