某低放废水处理站的调试运行 被引量:1

Commission and Operation of A Low Level Liquid Waste Treatment Station
下载PDF
导出
摘要 某新建低放废水处理站主要采用絮凝沉淀、超滤和离子交换工艺处理低放废水,其废水处理可根据不同需求进行工艺组合,所选用的絮凝沉淀+过滤+超滤+离子交换处理工艺,经调试与运行后,处理效率可达99.98%,出水浓度可降为0.2 Bq/L,处理后的废水满足排放要求。 A new low-level liquid waste treatment station mainly used flocculation sedimentation, ultrafiltration and ion exchange process to treat low-level liquid waste. The liquid waste treatment can be .combined according to different needs. The selected treatment process was floccnlation sedimentation + filtration + ultrafiltration + ion exchange. After commission and op- eration, the treatment efficiency can reach 99.98%, the effluent concentration can be reduced to 0.2 Bq/L, and the treated liq- uid waste met the emission requirements.
出处 《环境卫生工程》 2017年第1期77-79,共3页 Environmental Sanitation Engineering
关键词 低放废水处理 调试 排放 low level radioactive liquid waste treatment commission emission