期刊文献+

Intra-cavity round-trip loss measurement of all-solid-state single-frequency laser by introducing extra nonlinear loss 被引量:3

Intra-cavity round-trip loss measurement of all-solid-state single-frequency laser by introducing extra nonlinear loss
原文传递
导出
摘要 A scheme for measuring the intra-cavity round-trip loss of an all-solid-state single-frequency laser by inserting a type-I noncritical phase-matching nonlinear crystal introducing nonlinear loss into the resonator is presented.The intra-cavity round-trip loss is theoretically deduced by analyzing the dependence of the fundamental-wave(FW) and second-harmonic-wave(SHW) powers on the pump factor and the nonlinear conversion factor of the single-frequency laser and experimentally measuring them by recording different FW and SHW powers, which are decided by the temperature of the nonlinear crystal. The measured intra-cavity round-trip loss and pump factor are 4.84% and 6.91% W-1, respectively. The standard deviations of the measured intra-cavity round-trip loss and the pump factor are 0.26% and 0.07%, respectively. This scheme is very suitable for measuring the intra-cavity round-trip loss of a high-gain solid-state single-frequency laser. A scheme for measuring the intra-cavity round-trip loss of an all-solid-state single-frequency laser by inserting a type-I noncritical phase-matching nonlinear crystal introducing nonlinear loss into the resonator is presented.The intra-cavity round-trip loss is theoretically deduced by analyzing the dependence of the fundamental-wave(FW) and second-harmonic-wave(SHW) powers on the pump factor and the nonlinear conversion factor of the single-frequency laser and experimentally measuring them by recording different FW and SHW powers, which are decided by the temperature of the nonlinear crystal. The measured intra-cavity round-trip loss and pump factor are 4.84% and 6.91% W-1, respectively. The standard deviations of the measured intra-cavity round-trip loss and the pump factor are 0.26% and 0.07%, respectively. This scheme is very suitable for measuring the intra-cavity round-trip loss of a high-gain solid-state single-frequency laser.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第2期44-48,共5页 中国光学快报(英文版)
基金 supported by the Key Project of the Ministry of Science and Technology of China(No. 2016YFA0301401) the National Natural Science Foundation of China (Nos. 61405107, 61227902, and 61227015)
关键词 Phase matching Phase matching
  • 相关文献

同被引文献22

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部