期刊文献+

室内PM_(2.5)浓度控制模拟分析 被引量:3

Simulation analysis of indoor PM_(2.5) concentration
原文传递
导出
摘要 利用质量平衡方程建立了一次回风定风量系统室内PM_(2.5)浓度模型,并对新风PM_(2.5)浓度、新风量、室内污染源、过滤器效率、过滤器安装位置等因素对室内PM_(2.5)浓度的影响进行了模拟分析。模拟结果表明:新风PM_(2.5)浓度和室内污染源强度的变化对室内PM_(2.5)浓度均有较大影响;新风量越大,室内PM_(2.5)浓度受新风PM_(2.5)浓度变化的影响越大;将过滤器分别安装在送风段、新风段和回风段新风比为0.1时,过滤器安装在送风段效果最好,安装在新风段最差,新风比为0.8时,过滤器安装在送风段效果最好,安装在回风段最差;过滤器安装在送风段时,过滤器效率越高,室内PM_(2.5)浓度越低,波动越小。 In this study,an indoor PM2.5 concentration model of a primary-return-air constant-air-volume system was built based on a mass balance equation,and the impacts of various factors on the indoor PM2.5 concentration were analyzed,including the fresh air PM2.5 concentration fresh air volume,indoor air pollution source,filter efficiency,and filter location.The results showed that fresh air PM2.5 concentration and indoor air pollution source affected the indoor PM2.5 concentration;and as fresh air volume increased,it exerted greater influence on the indoor PM2.5 concentration.It was assumed that a single filter was used for either the supply,fresh air pr return airstreams.The highest reduction in indoor PM2.5 concentration was achieved by using a supply air filter,whether the fresh air ratio was 0.1 or 0.8;but the indoor PM2.5 concentration decreased the least with a fresh air or return air filter,as the fresh air ratio was 0.1 and 0.8,respectively.When the filter was used for the supply airstream,the increase in filter efficiency led to a lower indoor PM2.5 concentration.
作者 徐秀 张泠 刘忠兵 王英姿 吕晓慧 XU Xiu ZHANG Ling LIU Zhongbing WANG Yingzi LYU Xiaohui(School of Civil Engineering, Hunan University, Changsha 410082, China)
出处 《环境工程学报》 CAS CSCD 北大核心 2017年第3期1755-1760,共6页 Chinese Journal of Environmental Engineering
关键词 室内PM2.5 过滤器 影响因素 控制策略 indoor PM2.5 filter influence factors control strategies
  • 相关文献

参考文献4

二级参考文献44

共引文献30

同被引文献55

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部