摘要 人类疾病的产生首先来自于物质的异常 ,所以物质分析是诊断疾病的主要技术。根据人体内物质不同的特性和浓度来选择不同的测量方法和计量技术。本文对近 40年来超微量物质分析 ,如肿瘤标志、激素、维生素和病原等 ,给予简短的评论 ,它们的浓度低于 10 -6g/L 。 The disease Development of the human being comes from at first the substance abnormities. So the substance analisis is the chief technique to diagnose diseases. Different methods and metrological techniques should be selected for determination according to the different characteristics and concentration of the substances in our body. This article makes a breif review on the past development during the latest 40 years of the ultra-micro substance analisis such as tumor marker, hormone, vitamins and pathogeny etc. whose concentration is below 10 -6 g/L and an introduction to the future new technique.
作者 许叔祥
出处 《上海计量测试》 2002年第4期4-6,共3页 Shanghai Measurement and Testing
关键词 计量技术 医学超微量定量分析 放射免疫分析 化学发光免疫分析 粒子计数免疫分析 临床诊断 Medical Ultra-micro Quantitative Analysis Radio Immunoassay Chemiluminescence Particle Counting Immunoassay
  • 相关文献

参考文献9

  • 1仝文斌,陶其敏.自动化免疫分析的进展[J].中华医学检验杂志,1996,19(6):329-331. 被引量:19
  • 2[3]Charles WMT et al. Impact of Random-access Automation on the Immunoassay Laboratory. Laboratory Medicine, 1993; 24 ( 11 ): 717- 723
  • 3[4]Josefina MB. Evaluation of Ciba Corning ACS: 180 Automated Immunoassay System. Clin Chem, 1994; 40 (3): 407 - 410
  • 4[5]Daniel WC et al. Clinical Instrumentation(Immunoassay Analyzers).Analytical Chemistry, 1995; 18: 49 - 53
  • 5[6]Woodhead S. Chemiluminescence Immunassay: An Review. J Chin Ligand Assay, 1995; 18: 49 - 53
  • 6[7]Richard F et al. Chemiluminescence Immunoassay:An Alternative to RIA. Laboratory Medicine, 1996;21(4) :216 -222
  • 7[8]Blick KE. Specifications for the Selection of Automated Immunoassay Systems. J Clin Lidand Assay, 1996;19:220-228
  • 8[9]Jackson T et al. Immunometric Assay and Automation. J Clin Lidand Assay, 1996; 19: 121-125
  • 9[11]C.L. Cambiaso et al. Particle counting immunoassay (PACI-A)--A general method for detemination of antibodies, antigens and haptens. J. Immunol. Methods, 19: 33 - 44 1977

二级参考文献1

  • 1仝文斌,中华医学检验杂志,1996年,19卷

共引文献18

同被引文献41

  • 1韩志芳.微量加样器在实验教学中的正确使用与校准[J].中国卫生检验杂志,2005,15(6):757-758. 被引量:11
  • 2周强,张文,黄宪章,丁海明,徐宁,庄俊华,张秀明,梁伟雄.CENTAUR全自动化学发光免疫分析仪性能评价[J].实用医学杂志,2005,21(13):1469-1470. 被引量:8
  • 3王栩,林金明.化学发光免疫分析技术新进展[J].分析试验室,2007,26(6):111-122. 被引量:19
  • 4Djian R, Thibeauh E, MacNamara. Optimization and cost analysis of a semi-automated pipette verification system in a clinical laboratory[J]. Clin Chem, 2005, 51(6 Supple): A215.
  • 5American society for testing and materials. Standard specifications for piston or plunger operated volumetric apparatus[J]. Designation: E, 1993, 1154-1189.
  • 6Loria. A, Salas. R. Evaluation of pipertting systems, Part Ⅱ[J]. Precision and accuracy of precision dispensers. Rev Invest Clin. 1990, 42: 157-160.
  • 7全国流量容量计量技术委员会.JJG646-2006[S].北京:中国计量出版社,2006.
  • 8Curtis, RH. Performance verification of manual action pipettes[J]. American Clinical Laboratory. 1994, 12: 8.
  • 9McGown E, Hafeman D. Muhichannel pipettor performance verified by measuring pathlength of reagent dispensed into a microplate[J]. Anal Biochem, 1998, 258: 155-157.
  • 10陶义训主编.免疫学和免疫学检验[M].2版.北京:人民卫生出版社,1999,156.