摘要
建立了同时测定循环水中F^-、Cl^-、SO_4^(2-)的离子色谱法,与工厂原测定方法相比较,该方法节省了大量的人力、物力,并且测定更加快捷,精密度更好,回收率高,检出限低,达到了工厂环境预警监测方案中的测定要求。
This paper established a method for determination of fluorine, chlorine and sulfate in circulating water by Ion Chromatography. Compared with factory original datermination method, the method saved a lot of manpower and material resources, and determination is more quickly, the method has high precision, high recovery and low detection limit. The method meets the requirements of factory environmental monitoring program.
作者
张小军
ZHANG Xiao-jun(Shaoguan Smelter, Shaoguan 512024, China)
出处
《湖南有色金属》
CAS
2017年第1期75-77,共3页
Hunan Nonferrous Metals