摘要
以6月份成都某高校教室为研究对象,在开窗通风和可自由开启吊扇的条件下,现场测试了教室内的温度、相对湿度和风速等参数,通过问卷调查了学生对室内外热环境的主观热感觉,并与本地住宅和国内其他城市同类建筑的研究成果进行了比较。结果表明:71.8%的学生对该时段内的热感觉表示接受;热中性温度为25.96℃,热期望温度为25.89℃,热舒适温度范围为25.44~27.26℃,与ISO7730标准中提供的教室推荐设计温度上限基本一致;另外,教室中测试拟合的TSV斜率大于PMV斜率,表明对温度的敏感性,学生实际的感觉比PMV预测的变化要快,并且人员在教室中比住宅中对温度的变化感觉更灵敏。
Tests the indoor temperature, relative humidity and air velcity in the college classrooms in June of Chengdu. Surveys the subjective assessment of students on the indoor and outdoor thermal environment by questionnaires. The results show, 71.8% of the students accept the thermal sensation in this period; the thermal neutral temperature is 25.96℃and the thermal preferred temperature is 25.89℃, the thermal comfort temperature range of 80% is 25.44~27.26℃, the upper limit is consistence with the recommended classroom design temperature limit in ISO7730 standard; thermal sensation of the actual test is more sensitive than thermal sensation of PMV prediction in the classroom, and thermal sensation of in the classroom is more sensitive than thermal sensation of the residence.
作者
刘晓艳
向艳
Liu Xiaoyan Xian Yan(Architectural Engineering Institute, Chengdu Textile College, Chengdu, 611731)
出处
《制冷与空调(四川)》
2017年第1期96-101,共6页
Refrigeration and Air Conditioning
基金
校级自然科学科研项目<成都地区夏季人体热舒适状况调查研究>项目(编号:2010fzlk05)
关键词
高校教室
热舒适
热感觉
现场测试
设计温度
college classrooms
tehermal comfort
thermal sensation
field survey
design temperature