期刊文献+

1000MW燃煤机组引风机汽轮机真空偏低原因分析及改进 被引量:6

Low-vacuum Analysis and Improvement for Steam Turbine Driving Induced Draft Fan in a 1000MW Coal-fired Unit
下载PDF
导出
摘要 为降低机组厂用电率,部分燃煤电厂引风机采用汽轮机驱动,使汽轮机冷端优化复杂化。针对国内某1 000 MW燃煤机组引风机汽轮机真空偏低的问题,结合主机冷端优化,考虑电厂实际运行中的可操作性,提出切实可行的提高方法及最佳运行方案。 To reduce power consumption rate, the induced draft fan in some coal-fired power plants is driven by steam turbine, which makes the cold end optimization become more complex. To solve the low- vacuum problem occurring in the steam turbine driving induced draft fan of a 1 000 MW coal-fired unit, an applicable operation scheme was proposed, considering cold end optimization of the unit and actual operability of the scheme.
作者 杨彪 杨博 Yang Biao Yang Bo(Huaneng Haimen Power Plant, Shantou 515132, Guangdong Province, China)
机构地区 华能海门电厂
出处 《发电设备》 2017年第2期127-131,136,共6页 Power Equipment
关键词 汽轮机 冷端优化 凝汽器 真空 节能降耗 steam turbine cold end optimization condenser vacuum energy saving and consumption reduction