双能量减影技术在PICC术置管定位中的价值 被引量:1

The Value Of Dual Energy Subtraction Technique In The Location By Peripherally Inserted Central Catheter
下载PDF
导出
摘要 目的:探讨双能量减影技术在经外周静脉穿刺中心静脉置管胸片定位中的价值。材料与方法:从我院2015年1月至2015年6月行经外周静脉穿刺中心静脉置管后采用数字化X线摄影胸片定位的400位患者中,置管末端位置在胸片上显示不清晰的36位患者使用双能量减影技术拍摄胸片,分别获得三幅图像:标准DR图像、软组织图像、骨组织图像。结果:36位经外周静脉穿刺中心静脉置管患者进行双能量减影技术拍摄胸片,在骨组织图像中置管位置均可清晰显示。结论:双能量减影技术在经外周静脉穿刺中心静脉置管胸片定位中能更好地显示置管末端位置。 Purpose: To investigate the value of locating chest radiography with digital radiography (DR) -dual energy subtraction technique in peripheral inserted central venous catheter (PICC). Materials and Methods: Among 400 cases from January 2015 to June 2015 after PICC, 36 unclear images in the catheter terminals position on the chest radiography were performed by DR-dual energy subtraction. Three images were given individually: standard DR images, soft tissue images, bone tissue images. Results: 36 patients on the chest radiography performed by DR-dual energy subtraction after PICC displayed clear images in catheter terminals position in the bone tissue images. Conclusion: DR-dual energy subtraction in PICC on the chest radiography showed better position in catheter terminals.
作者 熊鼐 Xiong Nai(Department of imaging, Changzhou fourth people' s hospital, Jiangsu 213000)
出处 《现代医用影像学》 2016年第6期1089-1091,共3页 Modern Medical Imageology
关键词 数字化X线摄影 双能量减影技术 经外周静脉穿刺中心静脉置管 自动曝光控制 DR, dual energy subtraction technique, peripheral inserted central venous catheter, automatic exposure control
  • 相关文献

参考文献4

二级参考文献39

  • 1许晓云.PICC导管异位的原因分析及预防[J].中国实用神经疾病杂志,2007,10(8):124-125. 被引量:67
  • 2张彦,刘兵.40例外周中心静脉置管术的临床应用与护理[J].护理研究(下半月),2005,19(5):907-908. 被引量:36
  • 3郝美秀.外周静脉置入中心静脉导管的临床应用进展[J].职业与健康,2006,22(4):304-306. 被引量:4
  • 4Vano E.ICRP recommendations on ‘managing patient dose in digital radiology'[J].Radiat Prot Dosim,2005,114(1-3): 126-130.
  • 5Compagnone G.Radiation doses to patients using computed radiography,direct digital radiography,and screen-film radiography[M]//General methods and overviews,lung carcinoma and prostate carcinoma.Heidlberg:Springer Netherlands,2008: 109-128.
  • 6Persliden J.Digital radiology and the radiological protection of the patient[J].Eur Radiol Syllabus,2004,14(1): 50-58.
  • 7International Commission on Radiological Protection.ICRP Publication 93.Managing patient dose in digital radiology.A report of the International Commission on Raditional Protection[R].Oxford: Pergamon Press,2004: 807-815.
  • 8Aldrich J E,Duran E,Dunlop P,et al.Optimization of dose and image quality for computed radiography and digital radiography[J].J Digit Imaging,2006,19(2): 126-131.
  • 9Lana L,Silva A.Assessment of patient dose in digital systems[M]//Digital imaging systems for plain radiography.New York: Springer Science+Business Media,2013: 49-62.
  • 10Zhang ML,Chu CK.Optimization of the radiological protection of patients undergoing digital radiography[J].J Digit Imaging,2012,25(1): 196-200.

共引文献50

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部