摘要 设计了一种新型旋转切向流聚丙烯管式膜器。通过建立的旋转切向流强化微滤实验装置系统 ,测定了聚丙烯PA管式膜在不同SiO2 悬浮液浓度和不同流体压力下的膜通量及其相应的时间 ;同时还测定了与旋转切向流相同工况下轴向流PA管的膜通量。实验研究结果表明 ,旋转切向流强化微滤不但系统结构简单 ,而且PA管式膜稳态通量是轴向流稳态通量的 1 6 5~ 2 A new type of polypropylene tubular membrane module in rotating tangential flow was designed to experimentally study the polypropylene PA tubular membrane microfiltration flux.Through the experimental system of rotating tangential flow which was set up to enhance the microfiltration,the polypropylene PA tubular membrane fluxes of rotating tangential flow and axial flow were measured under different concentrations of SiO 2 suspension and different fluid pressures.The experimental results show that the rotating tangential flow membrane module to enhance microfiltration is not only energy saving but also simple in system structure,and the PA tubular membrane flux of rotating tangential flow is 1.6~2.5 times that of the axial flow.
出处 《环境工程》 CAS CSCD 北大核心 2002年第4期11-13,共3页 Environmental Engineering
基金 国家自然科学基金资助项目(No .2 99760 2 5) 四川省教委重点科研项目资助
关键词 对比试验 旋转切向流 轴向流 微滤 聚丙烯 膜通量 膜分离 废水处理 rotating tangential flow,axial flow,microfiltration,polypropylene and membrane flux