期刊文献+

不同蒸发器结构的超薄平板环路热管的传热性能的差异化 被引量:6

Multiple orientations research on heat transfer capabilities of ultra-thin loop heat pipes with various channel configurations
原文传递
导出
摘要 开发设计了两款无毛细结构的超薄型(1.5 mm厚)铜-水平板环路热管,并对其多方位下热传输性能进行实验研究.对比分析了两种蒸发器结构的热管在不同角度下的启动能力和运行特性,且探究了蒸发器结构对于超薄环路热管运行稳定性的影响,以及热管性能在多方位条件下的差异.实验表明两种结构热管均能满足多方位工作的要求,具有抗重力特性,其中平行四边形的结构设计有助于抑制流动不稳定,抗重力性能更优,不仅能够在15°时启动,而且不同角度下热传输性能的差异仅为4%. Battery thermal management system(BTMS) technology attracted more and more attentions as the new-energy automobile industry has gotten swift and violent progress in a few decades. So far, the widely used technologies include air cooling, liquid cooling and Phase Change Material(PCM) cooling. However, a common problem exists in all used technologies is the complex structures as well as the huge weight and volume, which not only increases the extra energy consuming, but also goes against the development requirement of automobile lighting. In the future, it is required without doubt that the battery thermal management system should be conveniently installed, light in weight and compact in volume, and minimized in secondary energy consumption. Thus, as a passive and effective heat transfer method, the heat pipe technology would be quite match the requirement and able to be further applied in BTMS. In order to cater to the developed requirement of lightweight design in battery thermal management system, ultra-thin loop heat pipe(ULHP) prototypes with only 1.5 mm in thickness were developed. The ultra-thin design was achieved by replacing the traditional capillary core structure with micro channels, which however required extra assistance from the gravity for the ULHP system to operate, and brought about the risk of flow instability at the same time. To fully understand the exact effect of channel configuration on the heat transfer performance of ULHP, and conquer the adverse impact caused by flow boiling in micro channels, two different channel configurations inside the evaporator(parallelogram and trapezoid) were special developed and compared. Their dissimilarities in heat transfer characteristic were studied and compared under multi orientations with experiments, which could be divided into various aspects, the critical work angle, as well as the start-up characteristic, the thermal resistance and the flow instability et al, so as to completely reflect the r respective influences of the parallelogram and trapezoid configurations on the operation and system stability of ULHP. The experiments results showed that both these two ULHP prototypes can work under small angles, meeting the demand of working under multiple orientations. Specially, the parallelogram evaporator configurations showed more superior performance with little gravity assistance by better suppressing the flow instability. This kind of ULHP could not only start up under 15° inclination, but also its average evaporator temperature difference between angles was limited in 4%, the largest difference was less than 10%. Nevertheless, the ULHP with trapezoid configuration couldn’t work until the placed angles increased to 30°, while its average evaporator temperature difference between angles and the largest difference for the trapezoid one achieved 7.8% and 20% respectively. The parallelogram configuration made contribution on ensuring the one-way forward circulation of the working fluid inside ULHP, the response of start-up process therefore was faster. The "liquid pool" structure formed in parallelogram configuration also played an important role in decreasing the pressure and temperature fluctuation and easing the flow instability, which not only enhanced the heat transfer capability of ULHP, but also effectively reduced the damage to the battery system. BTMS could work more stably with ULHP whose channel configuration inside the evaporator was in parallelogram.
出处 《科学通报》 EI CAS CSCD 北大核心 2017年第7期721-729,共9页 Chinese Science Bulletin
基金 新能源汽车用动力电池高性能的研究国际合作项目(2013DFG60080)资助
关键词 超薄 热传输性能 多方位 差异 运行稳定性 ultra-thin heat transfer characteristic multiple orientations differences operation stability
  • 相关文献

参考文献2

二级参考文献16

  • 1FENG JianTing,LIN GuiPing,BAI LiZhan.Experimental investigation on operating instability of a dual compensation chamber loop heat pipe[J].Science China(Technological Sciences),2009,52(8):2316-2322. 被引量:11
  • 2姚寿广,马哲树,陈如冰.一种新型结构的热管式散热冷板性能的数值模拟试验与分析[J].中国电机工程学报,2005,25(7):41-45. 被引量:16
  • 3Donald Gluck. Charlotte Gerhart and Scott Stanley.Startup of a Loop Heat Pipe with Initially Cold Evaporator, Compensation Chamber and Condenser. In: 11th IHPC Tokyo. Japan, 1999
  • 4Jane Baumann, Brent Cullimore, Eva Buchan. Noncondensible Gas, Mass and Adverse Tilt Effects on the Startup of Loop Heat Pipes. In: 29th ICES. Denver, Colorado,America, 1999
  • 5Tarik Kaya, Jentung Ku, Triem T H, et al. Investigation of Low Power Start-up Characteristics of a Loop Heat Pipe. STAIF, 1999
  • 6Jentung Ku. Operating Characteristics of Loop Heat Pipes. In: 29th ICES, Denver, Colorado, America, 1999
  • 7Michael Nikitkin. Evgenyi Kotlyarov and Gennadyi Serov. Basics of Loop Heat Pipe Temperature Control.In: 29th ICES. Denver, Colorado, America, 1999
  • 8Delil A A, Baturkin B, Khmelev Y, etal. Experimental Result of Heat Transfer Phenomena in a Miniature Loop Heat Pipe with a Flat Evaporator. In: 12th IHPC.Moscow, Russia, 2002
  • 9Chernyshev M A, Vershinin S V, Maidanik Yu F. Development and Tests of Miniature Loop Heat Pipe with a Flat Evaporator. In: 12th IHPC. Moscow, Russia, 2002
  • 10Jake Kime, Eric Golliher. Steady State Model of a Micro Loop Heat Pipe. In: 18th IEEE SEMI-THERM Symposium. 2002

共引文献33

同被引文献34

引证文献6

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部