摘要 目的评估常规随访对心脏植入性器械(CIED)患者生活影响,包括时间、费用和人力成本。方法本研究为多中心、前瞻性、观察性研究。CIED患者术后3个月到医院接受常规随访,并完善随访花费时间和费用的问卷调查。结果 2012年1月至2013年10月共入选161例患者,其中起搏器患者82例,埋藏式心脏转复除颤器患者39例,心脏再同步化治疗患者40例。患者年龄(62.3±14.29)岁,其中男性108例(67.08%)。患者平均花费150元。患者路途用时、挂号开单用时、检查前等待及检查时间分别为120、40、30及15 min,76.7%的患者需要陪同人员一同前往医院,67%的陪同人员需要请假。结论患者路途及检查前花费时间及由此产生住宿和交通的费用,大大增加了患者常规诊室随访的成本,远程监测随访可望大大节省患者的时间及金钱成本。 Objective To appraise the influence of conventional follow-up on the cardiac implanted electric devices (CIED) patients. Methods This was a multicenter, perspective and observational study, which enrolled patients who had been treated with CIED including pacemaker, implantable cardioverter defibrillators(ICD) and cardiac re- synchronization therapy(CRT). The patients were asked to do questionnaires about time and fee cost for the routine- ly follow-up 3 months after implantation. Results Totally 161 patiens from 12 medical centers, mean age of ( 62. 3±14.29)years old,67.08% male, were enrolled from January 2012 to October 2013. The average fee for follow-up was 150 yuan, mostly for the transportation and accommodation. The time-comsuming for transportation, register, periexamine waiting and CIED check-up was 120 min,40 min, 30 min and 15 min, respectively. 76.7% patients need family member company, 67% family member need ask for a leave. Conclusions The time consuming for transportation is a major component of the overall time-cost of conventional follow-up, so is the fee. Telemedi- cine-assisted long-term care may considerably reduce the time and fee cost.
出处 《中国心脏起搏与心电生理杂志》 2017年第1期8-11,共4页 Chinese Journal of Cardiac Pacing and Electrophysiology
关键词 心血管病学 心脏植入性器械 常规随访 问卷调查 Cardiology Cardiac implanted electricdevices Conventional follow-up Questionnaire survey
  • 相关文献

参考文献3

二级参考文献30

  • 1王方正,张澍,华伟,胡大一,陈新.全国心脏起搏器临床应用调查(2002至2005年)[J].中华心律失常学杂志,2006,10(6):475-478. 被引量:21
  • 2Epstein AE, DiMarco JP, Ellenbogen KA, et al. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Ab- normalities:a report of the American College of Cardiology/Ameri- can Heart Association Task Force on Practice Guidelines. ( Writ- ing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. J Am Coll Cardiol,2008,51 : e1-62.
  • 3Dickstein K,Vardas PE,Aurlcchio A, et al. 2010 focused update of ESC Guidelines on device therapy in heart failure : an update of the 2008 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure and the 2007 ESC Guidelines for cardiac and resynchronization therapy. Developed with the special contribu- tion of the Heart Failure Association and the European Heart Rhythm Association. Eur J Heart Fail,2010,12 : 1143-1153.
  • 4McMurray JJ, Adamopoulos S, Anker SD, et al. ESC Guidelines for the diagnosis and treatment of acute mad chronic heart failure 2012. Eur J Heart Fail,2012,14 : 803- 869.
  • 5Wilkoff BL, Auricchio A, Brugada J, et al. HRS/EHRA expert con- sensus on the monitoring of Cardiovascular Implantable Electronic Devices (CIEDs) : Description of techniques, indications, person- nel, frequency and ethical considerations. Europace, 2008, 10: 707-725.
  • 6Haycs DL, Naccarelli GV, Fuman S, et al. North American Society to Pacing and Electrophysiology. NASPE training requirements for cardiae implantable electronic devices: selection, implantation, and follow-up. Pacing Clin Eleetrophysiol,2003,26 : 1556-1562.
  • 7Naccarelli GV,Conti JB, DiMarco JP,et al. 2008 COCATS 3 Tack Force 6: training in specialized electrophysiology,cardiac pacing, and arrhythmia management. Heart Rhythm ,2008,5:332-337.
  • 8Schoenfeld MH, Reynolds DW. Sophisticated remote implantable cardioverter-defibrillator follow-up: a status report. Pacing Clin Electrophysiol, 2005,28 : 235 -240.
  • 9Joseph GK, Wilkoff BL, Dresing T, et al. Remote interrogation and monitoring of implantable cardioverter defibrillators. J Interv Card Electrophysiol,2004,11 : 161-166.
  • 10Varma N, Epstein AE, Irimpen A, et al. Efficacy and safety of au- tomatic remote monitoring for implantable cardioverter-defibrilla- tot follow-up: The Lumos-T Safely Reduces Routine Office De- vice Follow-up (TRUST) trial. Circulation,2010,122:325-332.