期刊文献+

经腋静脉和锁骨下静脉途径置入起搏器电极导线的对照研究 被引量:6

A comparative study on implantation of endocardial electrode via axillary vein and subclavian vein approaches
原文传递
导出
摘要 目的通过与锁骨下静脉穿刺置入起搏电极进行对照研究,探讨经腋静脉穿刺置入起搏器电极导线的可行性与安全性。方法入选118例起搏器植入患者,按简单随机法分为腋静脉组(n=66)与锁骨下静脉组(n=52),分别经腋静脉途径和经锁骨下静脉途径置入起搏导线。比较两种途径置入起搏导线的穿刺成功率和并发症。结果腋静脉组与锁骨下静脉组穿刺成功率分别为95.4%(63/66)和96.2%(50/52);两组并发症发生率分别为1.5%(1/66)和5.8%(3/52),两组患者穿刺成功率和并发症发生率均无统计学差异(P均>0.05)。其中,锁骨下静脉组发生气胸3例,腋静脉组无一例发生气胸(P<0.05)。结论经腋静脉途径置入心脏起搏器导线安全可行。 Objective To compare the safety and feasibility of axillary vein and subclavian vein approaches for im- plantation of endocardial electrode. Methods A total of 118 patients underwent placement of pacemaker via axilla- ry vein approach (axillary vein group) or subclavian vein approach (subclavian vein group). To compare the success rate and complication of two kinds of pacemaker implantation. Results The rate of success of the axillary vein and subclavian vein puncture group were 95.4% (63/66) and 96.2% (50/52); The incidence of complication in two groups was 1.5% (1/66) and 5.8% (3/52), two groups of patients had no significant difference in successful punc- ture rate and complication incidence rate(P〉0.05). Among them, 3 cases of pneumothorax occurred in the subcla- vian vein group, and there was no pneumothorax in the axillary vein group (P〈0.05). Conclusion It is safe and feasible to put the pacemaker lead through axillary vein.
出处 《中国心脏起搏与心电生理杂志》 2017年第1期26-28,共3页 Chinese Journal of Cardiac Pacing and Electrophysiology
关键词 心血管病学 腋静脉 锁骨下静脉 心内膜电极 Cardiology Axillary vein Subclavian vein Endocardial electrode
  • 相关文献

参考文献5

二级参考文献18

  • 1王龙.腋静脉穿刺技术[J].中国心脏起搏与心电生理杂志,2006,20(3):271-273. 被引量:40
  • 2Burke G A,Bekiroglu F,Martin TJ,et al.Transposition of the cephalic vein facilitated by an osseous subclavicular passage[J].Br J Oral Maxillofac Surg,2007,45(8):686.
  • 3Sarveswaran J,Burke D,Bodenham A.Cephalic vein cut-down verses percutaneous acces:a retrospective study of complications of implantable venous access devices[J].Am J Surg,2007,194(5):699.
  • 4Lau EW,Liew R,Harris S.An unusual case of the cephalic vein with a supraclavicular course[J].Pacing Clin Electrophysiol,2007,30(5):719.
  • 5Povoski SP,Young DC.Prospective randomized trial comparing implantation of subcutaneous indwelling venous access devices by the cephalic vein cutdown(CVC)approach versus the percutaneous subclavian vein(PSV)approach[J].Chir Ital,2003,55(1):149.
  • 6Yang J,Powell A,Davis M.Implantation of dual chamber pacemaker defibrillator and placement of endocardial leads via the axillary vein[J].Chin Mad J(Engl),2001,114(6):568.
  • 7Neri R,Cesario AS,Baragli D,et al.Permanent pacing lead insertion through the cephalic vein using an hydrophilic guidewire[J].Pacing Clin Eiectrophysiol,2003,26(12):2 313.
  • 8Di Carlo I,Barbagallo F,Toro A,et al.External jugular vein cutdown approach,as a useful alternative,supports the choice of the cephalic vein for totally implantable access device placement[J].Ann Surg Oncol,2005,12(7):570.
  • 9Chen JY,Chang KC,Lin KH,et al.Ultrasonographic predictors of unsuccessful cephalic vein approach during pacemaker or defibrillator lead implantation[J].Pacing Clin Electrophysiol,2006,29(7):706.
  • 10Excellence NIfC:Guidance on the Use of Ultrasound Locating Devices for Central Venous Catheters.(NICE Technology Appraisal,No.49.).2002.

共引文献68

同被引文献21

引证文献6

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...