期刊文献+

应用Pentacam系统测量晶状体密度在不同类型年龄相关性白内障诊断中的价值 被引量:4

Value of Applying Pentacam System to Measure Lens Density in Diagnosis of Different Types of Age-Related Cataract
下载PDF
导出
摘要 目的探讨应用Pentacam系统测量晶状体密度在不同类型年龄相关性白内障诊断中的价值,旨在提高白内障临床诊断的有效性。方法选取我院2010年9月至2015年4月收治的不同类型年龄相关性白内障患者176例,采用LOCSⅢ分级法对患者的白内障类型进行分级,并利用Pentacam系统对晶状体的密度进行测量。分析晶状体密度值、LOCSⅢ评分和Log MAR视力之间的关系。结果 NO、NC以及C分级与患者晶状体的密度表现出正相关,且晶状体的密度值与Log MAR视力之间的相关系数r=0.868。结论 Pentacam系统对晶状体的密度与NO、NC和C分级的测量具有较好的一致性;晶状体的密度可用于不同年龄相关性白内障的临床诊断。 Objective To explore the value of applying pentacam system to measure lens density in the diagnosis of different types of age-related cataract, in order to improve the effectiveness of clinical diagnosis of cataract. Methods 176 cases of patients with different types of age-related cataract admitted to our hospital fi'om September 2010 to April 2015 were selected. LOCS II1 classification method was used to classify patients' types of cataract, and Pentacam system was used to measure lens density. The relationship among the lens density, LOCS Ⅲ scores and LogMAR sight was also analyzed. Results The lens density of patients had positive correlation with the classifications of NO, NC and C. Besides, the correlation coefficient (r) between the lens density and LogMAR sight was 0.868. Conclusions Pentacam system has a preferable consistency towards lens density and the measure of NO, NC and C. Lens density can be used for clinical diagnosis of different types of age-related cataract.
出处 《临床医学工程》 2017年第3期289-290,共2页 Clinical Medicine & Engineering
基金 2013年国家自然科学基金项目(项目编号:81300731) 2015年广东省医学科研基金项目(项目编号:A2015041) 2015年中山市科技计划医疗卫生重大专项(项目编号:2015B1007)
关键词 白内障 PENTACAM系统 晶状体密度 Cataract Pentacam system Lens density
  • 相关文献

参考文献3

二级参考文献60

  • 1Falkner-Radler CI, Benesch T, Binder S. Accuracy of preoperative biometry in vitreetomy combined with cataract surgery for patients with epiretinal membranes and maealar holes: results of a prospective controlled clinical trial [ J ]. J Cataract Refract Surg, 2008,34 : 1754-1760.
  • 2Su WW, Chen PY, Hsiao CH, et al. Primaryphacoemulsifieation and intraocular lens implantation for acute primary angle-closure [ J]. PLoS One.2011. 6 : e20056.
  • 3He M, Huang W, Zheng Y, eL al. Anterior chamber depth in elderly Chinese: the Liwan eye study [ J ]. Ophthahnology, 2008, 115 : 1286-1290.
  • 41,adas JG, Stark WJ. hnproving cataract surgery Refiraetive Outcomes[ J]. Ophthahnology,2011,118:1699-1700.
  • 5Olsen T, Nielsen PJ. Immersion versus contact technique in the measurement of axial length by uhrasound [ J ]. Aeta Ophthahuol, 1989,67 : 101-102.
  • 6Haigis W. Pseudophakic correction factors tor optical hiometry [ J]. Graefes Arch Chin Exp Ophthalmol,2001,239 :589-598.
  • 7Kiss B, Findl O, Menapace R, el al. Refi'aetive outeome of cataract surgery using partial coherence intefferometry and uhrasound biometry: clinical feasibility study of a eummercial prototype II[ J ]. J Cataract Refract Surg,2002,28:230-234.
  • 8Rabsilber TM, Khoramnia R, Auffarth GU. Anterior ehamber measurements using Pentacam totaling Seheimpflug camera[ J]. J Cataract Refraet Surg,2006 ,32 :456-459.
  • 9Jivrajka RV, Shammas MC, Shammas HJ. Improving the seeond- eye refractive error in patients undergoing bilateral sequential cataract surgely[ J ]. Ophthalmology ,2012 , 119:1097-1101.
  • 10Colin J, Robinet A. Clear lensectomy aml implantation of a low- power posterior ehamber intraoeular lens for cetrectinn of high myopia : a four-year follow-up[ J]. Ophthalmology, 1997,104:73- 77.