结合新版《火灾自动报警系统设计规范》GB 50116—2013规定,以清远抽水蓄能电站火灾自动报警系统设计为例,阐述了蓄能水电站消防设计中几个常见问题的处理,处理方法可为类似工程提供借鉴。
Combined with " Code for design of automatic fire alarm system" GB50116 -2013, this paper takes the design of automatic fire alarm system in Qingyuan pumped storage power station as an example, solutions of several common problems in the fire protection design are introduced, which has a reference value for the similar engineering.