期刊文献+

对C.I.分散黄211检测中对氯苯胺呈假阳性结果的探讨 被引量:1

False Positive Detection for 4-Chloroaniline in C.I. Disperse Yellow 211
原文传递
导出
摘要 检测C.I.分散黄211中可裂解禁用芳香胺对氯苯胺时,结果可能存在假阳性。采用GC/MS检测技术进行分析,发现该假阳性检出物为对氯苯胺同分异构体-间氯苯胺,对它的来源进行推断及验证,得出间氯苯胺来源于对氯邻硝基苯重氮盐分解产物的结论,为检测以对氯邻硝基苯胺为原料合成染料中对氯苯胺提供了一定的参考。 A false positive determination for 4-chloroaniline maybe occur in detection of banned aromatic amines of C. I. Disperse Yellow 211. Based on GC/MS, the false positive determination was the isomeride of 4-chloroaniline--3-ehloroaniline, which produced from the secondary reaction of diazonium salt of 4-ehloro-2-nitroaniline. It was a reference for 4-ehloroaniline detection of azo dyes synthesized from 4-chloro-2-nitroaniline.
作者 李赵炆 胡惠素 商李金 孙岩峰 LI Zhao-wen HU Hui-su SHANG Li-jin SUN Yan-feng(Application Service Department of Zhejiang Ji-Hua Croup Company Limited, Hangzhou 311228, Zhejiang China)
出处 《染料与染色》 CAS 2017年第1期45-48,共4页 Dyestuffs and Coloration
关键词 C.I.分散黄211 对氯苯胺 间氯苯胺 假阳性 C. I. Disperse Yellow 211 4-chloroaniline 3-chloroaniline false positive