摘要 通过对国家、企业的技术标准、规范中智能电能表潜动试验方法的分析,结合智能电能表实际安装环境,找出现有试验方法存在的弊端,完善了智能电能表潜动试验的方法,在实验室搭建电磁兼容潜动试验环境下,对单相智能电能表进行潜动试验。通过两种试验结果对比分析,验证了电磁环境对智能电能表潜动性能具有一定影响。 In this paper,through analysis of the intelligent electric energy meter test method for false actuation test on specification,combining with actual installation environment,the defects and unreasonable of the existing test methods is found out,an electromagnetic compatibility environment of false actuation test in the laboratory is built,false actuation tests of all kinds of single phase intelligent electric energy meter is studied. The results shows the new methods and new requirements have a certain influence.
作者 尹博 刘莉 王佳晗 李菥然 赵影 YIN Bo LIU Li WANG Jiahan LI Xiran ZHAO Ying(School of Electrical Engineering, Shenyang Institute of Engineering, Shenyang, Liaoning 110136, China State Grid Liaoning Eleetric Power Co., Ltd., Metrolngical Center, Shenyang, Liaoning 110168, China Electric Power Research Institute of State Grid East Inner Mongolia Electric Power Co., Ltd., Hohhot, Inner Mongolia 010020,China)
出处 《东北电力技术》 2017年第2期34-37,共4页 Northeast Electric Power Technology
关键词 智能电能表 电磁兼容EMC 潜动 the intelligent electric energy meter electromagnetic compatibility EMC false actuation