摘要 超声波管道流量计的研发重点是对超声波在管道液体中顺流和逆流时差的测量,并通过信号处理等办法,将时间信息换算为速度信息,再转换为管道流体所对应的流量信息。采用高精度时差芯片TDC-GP2实现对超声波管道流量计中的声波时间差的测量。论述了时差法超声波管道流量计的基本原理,介绍了TDC-GP2时间测量芯片的功能原理和使用方法,简述了相关硬件电路和系统构成。结合以上原理方法,论证了超声波流量计可行的技术方案;通过对时差法测量原理的研究,设计了相关时差测量电路,以及显示电路、信号处理电路等电路,并完成了设备的调试和组装。超声波流量计可以有效解决非介入式的管道液体、气体等流量的实时测量。 The research priority of ultrasonic flow meter is measuring the time difference between ultrasonic through in the upstream and downstream of a conduit that having liquid flowing. Then the signal processing and other related method will be used to convert the time information into velocity information. Finally,the corresponding flow information of pipeline fluid will be calculated. In the paper,high- precision time measurement chip TDC-GP2 was applied to realize the measurement of time difference by ultrasonic flowmeter. The basic research and measuring principle of the time difference method ultrasonic pipe flow meter were discussed,on the one hand,the function-al theory and application method of high-precision time measurement chip TDC-GP2 have been introduced,on the other hand,the corre-sponding circuit design and system structure analysis have been presented as well. Combining the above principles approach and theo-ries, the feasible technical proposal of ultrasonic flowmeter has been provided, and based on study of the principle of time difference measurement,the time difference measurement circuit, the display circuit and the signal processing circuit are designed. Ultrasonic flowmeter can effectively solve the pipeline gas liquid,non intrusive real-time flow measurement.
作者 张涛
出处 《能源与环保》 2017年第3期124-127,共4页 CHINA ENERGY AND ENVIRONMENTAL PROTECTION
关键词 TDC-GP2 时差法 超声波流量计 测量精度 测量电路 TDC-GP2 time difference method ultrasonic flowmeter measuring accuracy measuring circuit
  • 相关文献

参考文献5

二级参考文献14

  • 1程利.时差式超声波流量计在污水计量上的应用[J].中国计量,2004(8):57-58. 被引量:5
  • 2仲峰,万莉萍,岳宇军.高精度时间测量芯片TDC-GP2在激光测距中的应用[J].工业控制计算机,2007,20(4):69-70. 被引量:24
  • 3潘琢金.C8051F410/1/2/3混合信号ISPFLASH微控制器数据手册[Z].2006.
  • 4ACAM. TDC - GP2 (Universal 2 Channel Time-to-Digital Convener) [ Z]. 2006.
  • 5张万江,陈胜昆,韩松.超声波热量表的设计[J].中国仪器仪表,2007(7):65-67. 被引量:5
  • 6M.Comes,P.Drumea,M.Blejan,I.Dutu1 and A.Vasile.ULTRASONIC FLOWMETER[J].Electronics Technology.2006,May:386-389.
  • 7刘博超.一种基于TDC的激光测距传感器实现.电子测量与仪器学报,2008,22(2).
  • 8ACAM 公司.TDC -GP2datasheet. [EB/OL]. (2011-2-11) [2011-5-10].http ://wenku.baidu.com/view/588b587831b 765ce0508149e.html.
  • 9TDC-GP2 Universal 2 Channel Time-to-Digital Converter.ACAM
  • 10曾庆勇.微弱信号检测[M].浙江:浙江大学出版社,2005