期刊文献+

核电厂EDI电除盐装置与传统混床水处理的对比分析 被引量:4

Comparison and Analysis of EDI Equipment in Haiyang NPP with Conventional Mixed Bed Water Treatment
下载PDF
导出
摘要 海阳核电厂蒸汽发生器排污系统采用了目前国际先进的EDI电除盐装置,该文章通过对比传统核电厂蒸汽发生器排污系统水处理方式,详细介绍了EDI电除盐装置,并对其工作原理、特点等进行浅析,得出了EDI电除盐装置较传统混床水处理更加稳定节能环保的结论。 International advanced EDI technology is adopted in the steam generator blowdown water system in Haiyang NPP.By contrasting with conventional mixed bed water treatment of steam generator blowdown system,the paper introduces the EDI device,and analyzes its operating principles,characteristics and prospect.Finally,it concludes that the EDI technology is more energy saving and more environmental protection than conventional mixed bed water treatment.
作者 刘中正
出处 《中国核电》 2017年第1期110-113,共4页 China Nuclear Power
关键词 EDI 蒸汽发生器排污 连续电除盐 水处理 水净化 EDI steam generator blowdown electrodeionization water treatment water purification
  • 相关文献

参考文献2

二级参考文献9

  • 1Wilkins F R, Mcconnelee P A. Continuous deionization in the preparation of microelectronics-grade water [J]. Solid State Technol, 1988, 31(8): 87-92.
  • 2Parise P L. Demineralization: The use of Ionpure continuous deionization for the production of pharmaceutical and semiconductor grades of water [J]. Ultrapure water, 1990, 7(8), 14- 28.
  • 3Ganzi G C, Parise P L. The production of pharmaceutical grades of water using continuous deionization post-reverse osmosis [J]. J Parenter Sci Technol, 1990, 44(4): 231- 241.
  • 4Yeon K H, Song J H, Moon S H. A study on stack configuration of continuous electrodeionization for removal of heavy metal ions from the primary coolant of a nuclear power plant [J]. Water Res, 2004, 38(7) : 1911 - 1921.
  • 5Yeon K H, Moon S H. A study on removal of cobalt from a primary coolant by continuous electrodeionization with various conducting spacers [J]. Separ Sci Technol, 2003, 38(10): 2347 -2371.
  • 6Yeon K H, Moon S H. Transport characteristics of Co^2+ through an ion exchange textile in a continuous electrodeionization (CEDI) system under electro-regeneration [J]. Separ Sci Technol, 2004, 39(15) : 3601 - 3619.
  • 7Yeon K H, Song J H, Moon S H, et al. Preparation and characterization of immobilized ion exchange polyurethanes (IEPU) and their applications for continous electrodeionization (CEDI) [J]. Korean J Chem Eng, 2004, 21(4) : 867 -873.
  • 8Yeon K H, Song J H, Kim J B, et al. Preparation and characterization of UV-grafed ion-exchange textiles in continous electrodeionization [J]. J Chem Technol Biot, 2004, 79(12) : 1395- 1404.
  • 9管山,王建友,王世昌.电去离子(EDI)过程处理电镀废水的研究进展[J].化工进展,2003,22(8):837-840. 被引量:6