摘要 对厚度分别为0.8,1.0,1.2,1.5,1.8,2.0 mm,长度为3 m的18个冷弯薄壁帽型截面立柱进行轴压试验,并采用国内外规范及理论计算方法对立柱轴压承载力进行计算和比较。研究表明:当帽型截面的厚度较小(0.8,1.0 mm)时,立柱先局部失稳,而后发生整体弯曲或弯扭失稳;而当截面厚度较大(1.2,1.5,1.8,2.0 mm)时,立柱则直接发生整体的弯曲或弯扭失稳。采用AISI S100-2007中直接强度法计算出的帽型截面轴压承载力与试验值总体接近;当厚度为1.5,1.8 mm时,采用GB 50018—2002、AISI S100-2007和BS EN1993-1-3∶2006的计算结果与试验值吻合良好;当厚度为1.0,2.0 mm时,除BS EN1993-1-3∶2006外,中国、美国标准计算结果与试验值相差均较大,达到10%~21%。 Axial compression tests were conducted for 18 cold-formed hat-section steel columns with length of 3meters and thickness of 0. 8,1. 0,1. 2,1. 5,1. 8 and 2. 0 mm. The axial compression loading capacities of the columns were calculated based on the domestic and overseas specifications and theoretical methods,whose results were compared with the testing results. The research results showed that when the thickness was small( 0. 8 and 1. 0mm),the column would locally buckle first,and then overall bending or flexural-torsional buckling occurred. When the thickness was large( 1. 2,1. 5,1. 8 and 2. 0 mm),the overall bending or flexural-torsional buckling would occur in the column. The axial compression bearing capacity calculated by DSM in AISI S100-2007 was close to test results. When the thickness was 1. 5 and 1. 8 mm, the calculation results were in good agreement with the experimental value based on GB 50018—2002,AISI S100-2007 and BS EN1993-1-3∶ 2006. When the thickness was 1. 0 and 2. 0 mm,the calculation results had 10% ~ 21% difference with the experimental value based on Chinese and North Ameriean specifications and theoretical method except European specification.
出处 《工业建筑》 CSCD 北大核心 2017年第3期169-174,共6页 Industrial Construction
基金 湖北省科技支撑计划(2014BAA122) 2015年度湖北省建设科技项目计划
关键词 冷弯薄壁帽型截面 立柱 轴压试验 轴压承载力 计算比较 cold-formed steel hat-section column axial compression test axial bearing capacity calculation and comparison
  • 相关文献

参考文献3

二级参考文献9

  • 1陈骥.钢结构稳定理论和设计[M].北京:科学出版社,2006.
  • 2孙绍文.钢结构构件的稳定[M].北京:冶金工业出版社,1991.
  • 3ANSI/AISC 360 - 05 LRFD 2005. An American National Standard Speciafication for Structural Steel Buildings [ S ]. Chicago, IL, March ,2005.
  • 4GB50017-2003.钢结构设计规范[S].[S].,..
  • 5GB50018—2002冷弯薄壁型钢技术规范
  • 6普通混凝土力学性能试验方法标准[S].GB/T50081-2002,2002
  • 7童根树.钢结构的平面内稳定[M].北京:中国建筑工业出版社,2004.
  • 8查达维.轻钢骨架轻质混凝土组合墙体抗侧性能有限元分析[D].武汉:武汉理工大学,2015.
  • 9程艳珍.外包发泡混凝土角钢龙骨墙柱轴压试验与有限元分析[D].武汉:武汉理工大学,2015.