文章针对某工作船2台主机并联运行时出现的异常停车故障现象,进行故障原因分析,通过现场调整PID参数,并在高负荷下进行测试,经过长时间运行,无异常停车现象发生,验证了该处理方案的有效性,最终解决了故障问题。
In regard to the abnormal shutdown of the two main engines of certain workboat during parallel running, all the possible influencing factors are analyzed for seeking solutions to solve the problem. The specific measure is to adjust PID parameters at site and to conduct test under heavy load. After a long time of running, no abnormal shutdown is found. As a result, the effectiveness of this solution is verified.
出处
《中国修船》
2017年第2期1-4,共4页
China Shiprepair
关键词
电子调速器
异常停车
PID参数
electronic governor
abnormal shutdown