摘要
采用紫外分光光度法测定了端羟基环氧乙烷-四氢呋喃共聚醚中抗氧剂的含量,测试条件为:检测波长282 nm,样品质量浓度4 mg/m L,放置时间5 min。其结果的相对标准偏差≤1.0%,极差≤0.002 0%。
The antioxidant content in the hydroxyl-terminated ethylene oxide-tetrahydrofuran copolyether was determined by using the ultraviolet spectrophotometry. The determination conditions are the test wavelength of 282 nm, the mass concentration of sample of 4 mg/mL, the placing time of 5 min. The relative standard deviation of the result is less than 1.0%, and the range is not more than 0.002 0%.
作者
王勇
王梦楠
赵小红
高雅
刘明雪
Wang Yong Wang Mengnan Zhao Xiaohong Gao Ya Liu Mingxue(Liming Research & Design Institute of Chemical Industry Co., Ltd., Luoyang 471000, China)
出处
《化学推进剂与高分子材料》
CAS
2017年第2期92-94,共3页
Chemical Propellants & Polymeric Materials
关键词
端羟基环氧乙烷-四氢呋喃共聚醚
芳香基受阻酚
紫外分光光度法
hydroxyl-terminated ethylene oxide-tetrahydrofuran copolyether
aryl hindered phenol
ultraviolet spectrophotometry