摘要 为了得到基于最少疏散时间和短暂聚集时间原则的铁路隧道紧急救援站疏散设施设计参数,采用building-EXODUS人员疏散仿真计算软件,考虑人员疏散的特点、速度及路径等因素,对不同横通道间距、横通道宽度和站台宽度等参数组合下的人员疏散时间进行计算。研究得到:1)紧急救援站疏散横通道的间距不大于60 m,宽度不小于3.5 m;2)17节车厢编组的普速列车紧急救援站站台的长度不小于500 m,站台高度不低于0.3 m,站台宽度不小于2.5 m。 The evacuation time in different combinations of parameters of spacing and width of evacuation passageway and width of platform is calculated by building-EXODUS simulation software considering characteristics, speed and path of evacuation, so as to improve the design parameters of evacuation facility of emergency rescue stations in long railway tunnel based on the principle of the minimum evacuation time and short gathering time. The study results show that: 1 ) The spacing of evacuation passageways should be smaller than 60 m, of which the width should be larger than 3.5 m. 2) The length of emergency rescue station platform of ordinary speed train with 17 carriages should be larger than 500 m, of which the height should higher than 0.3 m, and of which the width should larger than 2.5 m.
作者 王明年 李琦 于丽 WANG Mingnian LI Qi YU Li(School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China Key Laboratory of Transportation Tunnel Engineering, Ministry of Education, Southwest Jiaotong University, Chengdu 610031, Sichuan, China)
出处 《隧道建设》 北大核心 2017年第3期285-290,共6页 Tunnel Construction
基金 国家自然科学基金(51308472) 中国铁路总公司科技研究开发计划课题(2014G004-C) 中国铁路总公司科技研究开发计划课题(2015T004-B) 西南交通大学博士研究生创新基金
关键词 长大铁路隧道 紧急救援站 火灾 疏散设施 疏散时间 聚集时间 long railway tunnel emergency rescue station fire evacuation facility evacuation time gathering time
  • 相关文献

参考文献7

二级参考文献45

共引文献88

同被引文献86

引证文献15

二级引证文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部