期刊文献+

断指、断肢再植术中的电子气压止血仪的应用和护理干预观察 被引量:1

Observation on application of electronic air pressure hemostasis instrument in severed finger and limb reimplantation and nursing intervention
下载PDF
导出
摘要 目的分析断指、断肢再植术中电子气压止血仪的应用效果,总结最佳止血方案。方法 80例行断指、断肢再植术的患者,随机分为对照组和观察组,每组40例。对照组行常规止血带止血,观察组采用电子气压止血仪止血,且两组均进行护理干预,观察分析两组患者的止血效果。结果观察组总止血满意度95.0%高于对照组的75.0%,差异具有统计学意义(P<0.05)。观察组舒适度评分为(0.4±0.7)分,明显优于对照组的(1.5±1.1)分,差异具有统计学意义(P<0.05)。观察组术后总并发症发生率5.0%低于对照组的20.0%,差异具有统计学意义(P<0.05)。结论在断指、断肢再植术中应用电子气压止血仪能起到较好的止血效果,联合针对性的护理干预则能更好促进止血治疗的顺利进行,有利于患者的恢复,应用价值较高。 Objective To analyze application effect by electronic air pressure hemostasis instrument in severed finger and limb reimplantation, and to summarize the preferred hemostasis scheme. Methods A total of 80 patient in severed finger and limb reimplantation were randomly divided into control group and observation group, with 40 cases in each group. The control group received conventional tourniquet for hemostasis, and the observation group received electronic air pressure hemostasis instrument. Both groups received nursing intervention. Observation and analysis was made on hemostasis effects in the two groups. Results The observation group had higher total hemostasis satisfaction as 95.0% than 75.0% in the control group, and the difference had statistical significance(P0.05). The observation group had obviously better comfort score as(0.4±0.7) points than(1.5±1.1) points in the control group, and the difference had statistical significance(P0.05). The observation group had lower total incidence of postoperative complications s 5.0% than 20.0% in the control group, and the difference had statistical significance(P0.05). Conclusion Implement of electronic air pressure hemostasis instrument in severed finger and limb reimplantation shows excellent hemostasis effect. Combing with targeted nursing intervention, this method can remarkably accelerate successful hemostasis treatment. It is beneficial for rehabilitation in patients, along with high application value.
出处 《中国实用医药》 2017年第5期155-157,共3页 China Practical Medicine
基金 湛江市科技局项目(项目编号:2016B101)
关键词 断指、断肢再植术 电子气压止血仪 护理干预 Severed finger and limb reimplantation Electronic air pressure hemostasis instrument Nursing intervention
  • 相关文献

参考文献8

二级参考文献62

  • 1裴国献.断肢(指)再植康复观念的更新与对策[J].中华显微外科杂志,1995,18(3):169-172. 被引量:89
  • 2李良荣,范晓炜,密其芳.断指再植术后血管危象分析与护理[J].华北煤炭医学院学报,2006,8(2):243-244. 被引量:16
  • 3李凤仁,高建平,王建.同理心在护患沟通中的应用[J].护理学杂志(综合版),2006,21(11):72-74. 被引量:64
  • 4胥少汀,葛宝丰,徐印坎.实用骨科学[M].3版.北京:人民卫生出版社,2005:576.
  • 5Battiston B,Tos P, Clemente A, et al. Actualities in big segments re- plantation surgery [J ]. J Plast Reconstr Aesthet Surg,2007,60 (7) : 849-855.
  • 6Jones NF,Schneeberger S. Arm transplantation:prospects and vi- sions[J]. Transplant Proc ,2009,41 (2) :476-480.
  • 7Hamel AL, Moe FH. Efect of total ischemia on hind limbs of dogs subjected to hypothermia [ J ]. Surgery, 1964,55 (6) : 274-280.
  • 8Fang CL, Yang CS,Tang HC, et al. Successful replantaion of ampu- tated bilateral lower limbs [J ~. Plast Reconstr Surg, 2012,129 ( 11 ) : 215-217.
  • 9Bhargava S, Namder R, Dutta S, et al. Immediate fixed temporiza-tion with a natural tooth crown pontic following failure of replanta- tion [ J ]. Contemp Clin Dent, 2011,2 ( 3 ) : 226-229.
  • 10Werder P, von Arx T, Chappuis V, et al. Treatment outcome of 42 replanted permanent incisors with a median follow-up of 2.8 years [ J ]. Schweiz Monatsschr Zahnmed, 2001,12 (4) : 312-320.

共引文献43

同被引文献6

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部