摘要 测量不确定度是对测量结果质量的定量表征,测量结果的可用性取决于其不确定度的大小,测量结果必须附有不确定度说明才是完整并有意义的。针对中厚板Q420NHY材料进行了拉伸试验中抗拉强度、下屈服强度、断后伸长率的不确定度评定。结果表明,对于抗拉强度,测量重复性引入的不确定度最为显著,对于下屈服强度,拉伸速率的影响最大,对于断后伸长率测量重复性及断后伸长的测量引入的不确定度最大。在包含概率取95%情况下,抗拉强度、下屈服强度、断后伸长率的扩展不确定度分别为2.4%、2.5%、2.9%。 Measurement of uncertainty is a quantitative characterization of the quality of the measurement results, the availability of the measurement results depends on the size of the uncertainty. The measurement result must be accompanied by instructions of uncertainty to be complete and meaningful. The evaluation of tensile strength, lower yield strength, elongation after fracture uncertainty of tensile test on bridge steel of Q420NHY plate is implemented. The results show that repeatability induced uncertainty is the most significant for tensile strength measurement, tensile rate induced uncertainty is with the greatest impact for lower yield strength; measurement repeatability and elongation measurement induced uncertainty is the maximum for the elongation after fracture uncertainty evaluation. When contain probability is set at 95%, expanded uncertainty of tensile strength, lower yield strength and percentage elongation after fracture are respectively 2.4%, 2.5%, 2.9%.
作者 薛欢 Xue Huan(Research & Development Center of WISCO, Wuhan 430080, Hube)
机构地区 武钢研究院
出处 《武汉工程职业技术学院学报》 2017年第1期11-14,共4页 Journal of Wuhan Engineering Institute
关键词 不确定度 桥梁钢 抗拉强度 下屈服强度 断后伸长率 测量误差 uncertainty bridge steel tensile strength lower yield strength percentage elongation after fracture measurement error
  • 相关文献

参考文献1

二级参考文献7

  • 1[1]BIPM, IEC, LFCC, ISO, IUPAC, IUPAP, OIML. Guide to the Expression of Uncertainty in Measurement. Corrected and Reprinted GUM) [ M]. Geneve Switerland: ISO, 1995
  • 2[3]GB/T1541-2000 idt ISO/IEC 17025:1999,检测和校准实验室能力的通用要求[S]
  • 3[5]中国实验室国家认可委员会认可文件汇编.CNAL/AC01:2002(ISO/IEC 17025:1999)检测和校准实验室认可准则[M].北京:中国计量出版社,2002.51-75
  • 4[6]中国实验室国家认可委员会认可文件汇编.CNAL/AR 11:2002测量不确定度政策[M]北京:中国计量出版社,2002.48-50
  • 5JJF1059-1999.测量不确定度评定与表示.[S].国家质量技术监督局发布,1999-05-01实施..
  • 6中国实验室国家认可委员会.中国实验室注册评审员培训教程[M].北京:中国标准出版社,2001.08..
  • 7李慎安.测量不确定度评定与表示研讨会报道之四 国际情况与合格判断[J].中国计量,2003(1):66-67. 被引量:3