摘要 地下岩土原始温度和运行中温度场变化是决定地能利用系统设计及能否长期稳定运行的关键因素.本文通过监测严寒地区大型地源热泵工程运行重要参数,特别是利用地下换热系统设置地下岩土温度监测孔,通过监测系统采暖期、制冷期和间歇期1年运行过程中,地下孔群纵向和径向岩土温度对负荷的响应及地温恢复情况,讨论热泵机组地温变化能效影响规律,为严寒地区地能利用系统实际工程运行及设计提供有效参考. The initial soil temperature and the change of underground temperature field in operation are the key factors for system design and long term stable operation for using geothermal energy system. By monitoring important operation parameters of a large ground source heat pump (GSHP) project in severe cold region, especially the temperature measuring devices have been set in monitor holes to measure the horizontal and vertical variation and the restoration of soil temperature field for the response of load in heating period, cooling period and intermittent period of the year. By the rule of the influence of the coefficient of performance (COP) of the heat pump for the variation of soil temperature, it provides valid reference for project operation and design for using geothermal energy system in severe cold area.
作者 齐子姝 高青 刘研 白莉 QI Zishu GAO Qing LIU Yan BAI Li(Key Laboratory of Songliao Aquatic Environment, Ministry of Education, Jilin Jianzhu University, Changchun 130118, China State Key Laboratory of Automotive Simulation and Control, Jilin University, Changehun 130025, China Department of Thermal Energy Engineering, Jilin University, Changchun 130025, China)
出处 《应用基础与工程科学学报》 EI CSCD 北大核心 2017年第1期37-45,共9页 Journal of Basic Science and Engineering
基金 国家自然科学基金项目(51376080) 吉林省科技厅青年科研基金项目(20160520028JH) 吉林省教育厅项目(吉教科合字〔2016〕第149号) 住房和城乡建设部科学技术计划项目(2016-K1-030)
关键词 地能利用 温度场 能效比 系统运行 geothermal energy utilization temperature field COP system operation
  • 相关文献

参考文献2

二级参考文献51

  • 1李新国,赵军,周倩.U型垂直埋管换热器管群周围土壤温度数值模拟[J].太阳能学报,2004,25(5):703-707. 被引量:52
  • 2李丽新,赵军,汪洪军,李新国,张鑫,贾贵喜.地下耦合地源热泵计算机测控系统的设计与实验研究[J].太阳能学报,2005,26(4):463-467. 被引量:7
  • 3赵军,王华军,宋著坤,陈志豪,李新国.U型管埋地换热器长期性能的实验研究与灰色预测[J].太阳能学报,2006,27(11):1137-1141. 被引量:15
  • 4Lei T K.Development of a computational model for a ground-coupled heat exchanger[J].ASHRAE Transactions,1993,99 (1):149-159.
  • 5Chiasson A C,Rees S J,Spitler J D.A preliminary assessment of the effects of ground -water flow on closedloop ground-source heat pump systems[J].ASHRAE Transactions,2000,106 (1):380-393.
  • 6Wang H J,Zhao J,Chen Z H,et al.Numerical study on the ground temperature field around large-area compact U-shaped pile-buried heat exchangers[C].Proceedings of 3rd Asian Conference on Refrigeration and Air-conditioning,Gyeongju,Korea,2006,(1):109-112.
  • 7Commercial/institutional ground-source heat pump en- gineering manual [ M ]. Atlanta: American Society of Heating Refrigerating and Air-conditioning Engineer- ings, Inc, 1995.
  • 8Gilbreath C S. Hybrid ground source heat pump system for commercial application[ D]. Master's thesis. Uni- versity of Alabama. Tuscaloosa. 1996.
  • 9Kavanaugh S P. A design method for hybrid ground- source heat pumps [ J ]. ASHRAE Transactions, 1998, 104(2) :691-698.
  • 10Phetteplace G, Sullivan W. Performance of a hybrid GCHP system[ J] . ASHRAE Transactions, 1998,104 ( 1 ) :763-770.