摘要
目的找出医用加速器充电辅助电路设计的原理和方法。方法该方法主要从物理原理出发,力图避免复杂的数学公式,分析波形频率和产生波形的电路源头。结果通过使用临界阻尼电路,完成完整的脉冲调制器的调整。结论通过对突出电路的主要因素进行分析,达到了与实际的辅助电路设计和验证基本吻合并得到了很好的验证。
Objective To find out the principle and method of the design of charging auxiliary circuit of medical accelera- tors. Methods The method is mainly base on the physical principle and trying to avoid the complex mathematical formula in the analysis of waveform frequency and waveform source circuit. Results Through the use of critical damping circuit, com- plete the full adjustment of pulse modulator. Conclusion Through the analysis of the main factor of the circuit, the actual auxiliary circuit design and verification are consistent and obtained a good verification.
出处
《中国辐射卫生》
2017年第1期96-99,共4页
Chinese Journal of Radiological Health
关键词
充电电路
阻尼电路
反尖峰电路
Charging Circuit
The Damping Circuit