期刊文献+

基于嵌入式平台的智能剩余电流动作断路器的电路设计 被引量:3

Circuit Design of Intelligent Residual Current Operated Circuit Breaker Based on Embedded Platform
下载PDF
导出
摘要 介绍一种安全用电领域的智能剩余电流动作断路器,主要是用来在设备发生漏电故障时以及对人有致命危险时的人身触电保护,具有过载和短路保护功能,可用来保护线路或电动机的过载和短路,它的特定电击波形识别功能对人身触电危险提供间接接触保护,把人身触电事故率和剩余电流动作断路器的误动跳闸率降至最低,保护用电的安全稳定工作。 The main body of a book describes an area of safe use of intelligent residual current operated circuit breaker,is mainly used for equipment in the event of leakage failure and the Fatal electrical shock protection,with overload and short circuit protection,can be used to protect the line or motor overload and short circuit,and its specific shock waveform recognition function provides indirect contact protection against the risk of personal electrical shock and reduces the rate of personal electrical shock and the trip rate of the residual current operated circuit breaker to Minimum.
作者 吴旻 周朝奎
出处 《工业控制计算机》 2017年第3期134-135,共2页 Industrial Control Computer
关键词 剩余电流动作断路器 嵌入式 漏电流 重合闸 触电 residual current operated circuit-breaker embedded leakage current reclosing electric shock
  • 相关文献

参考文献4

二级参考文献12

  • 1GB13955--2005剩余电流动作保护装置安装和运行[s].
  • 2中国航空工业规划设计研究院.工业与民用配电设计手册[M].3版.北京:中国电力出版社,2005.
  • 3JGJ 16-2008 民用建筑电气设计规范[S].
  • 4GB50054--2011低压配电设计规范[S].2012.
  • 5马辉.配电设备[M].北京:中国电力出版社,2010.
  • 6GB/Z6829-2008(IEC/TR60755:2008,MOD)剩余电流动作保护电器的一般要求[s].
  • 7GB16895.4-1997(idtIEC364-5-53:1994;IEC364-5-537:1981)建筑物电气装置第5部分:电气设备的选择和安装第53章:开关设备和控制设备[s].
  • 8王厚余.电子式RCD和电磁式RCD的选用[J].建筑电气,2010,29(2):3-6. 被引量:9
  • 9陈水生.PLC在漏电断路器出厂检测系统中的设计[J].中国高新技术企业,2011(7):77-78. 被引量:1
  • 10余存泰.剩余电流动作断路器电路优化设计[J].低压电器,2013(15):26-28. 被引量:5