摘要
通过对危急遮断器的性能分析,得出危急遮断器在脱钩、复位时的运动特性,并搭建试验台对危急遮断器的性能进行试验研究。试验结果验证设计方法的可行性并为危急遮断器设计提供参考。
According to the performance analysis of emergency trip device, motion characteristics of emergency trip device at two procedures (after trip and restore) are obtained The test facilities are built to make an experimental study upon the performance of the emergency trip device. The experimental result verifies the feasibility of the design method and provides useful information for design of the emergency trip device.
出处
《机电设备》
2017年第2期32-35,共4页
Mechanical and Electrical Equipment
关键词
危急遮断器
运动特性
汽轮发电机
emergency trip device
motion characteristics