摘要
文章详述了DZZ5型自动气象站的1次气温偏低故障的处理过程,并尝试用不同的方法探索故障发生的原因,发现是由于系统电源存在问题所致,改进电源线路后故障得以排除。为今后解决自动气象站类似故障提供参考。
A low temperature fault of DZZ5 automatic weather station is discussed in detail in this paper.Trying different methods to figure out the fault,eventually it found that it is caused by the system power supply.The fault is eliminated after the power circuit was improved,providing references to deal with similar faults of automatic weather stations in the future.
出处
《气象水文海洋仪器》
2017年第1期31-33,共3页
Meteorological,Hydrological and Marine Instruments