摘要
简介热泵式溶液除湿空调系统的原理,通过案例来分析热泵式溶液除湿空调系统设计的要点。由i-d图分析热泵式溶液除湿空调设备的新风状态点以及干盘管承担的负荷。
This paper introduces the principle of heat solution dehumidification air conditioning system, analyzes the design points of heat solution dehumidification air conditioning system through the case. Analysis of fresh air state point and dry coil load of dehumidification solution dehumidification air conditioning equipment by i-d graph.
关键词
热泵式溶液除湿空调
温湿度独立控制
i-d图
heat solution dehumidification air conditioning
humiture independent control
i-d diagram