摘要 考虑到医院内部区域,特别是患者长期居住的病房的特殊作用,以及医院内环境的特点,沿用住宅的设计参数已然不能完全满足患者对舒适度的要求。本文通过使用PMV-PPD指标方法对医院建筑室内环境的设计参数作出理论分析,确定了若干组可以使PPD≈5%的室内温、湿度,为以后的医院空调设计提供了参考。 Taking into account the region within hospital, particularly the special effects of long-term residents of ward patients, and the characteristics of hospital environment, adopting residential design parameters can not meet the patients' requirements of comfort. In this paper, hospital design parameters of indoor environment has been theoretical analyzed with PMV-PPD index, and several groups of indoor temperature and humidity which can make the PPD index to be 5% has been determination, which will provide a reference for the air conditioning system design in the future.
出处 《建筑热能通风空调》 2017年第3期33-35,46,共4页 Building Energy & Environment
关键词 医院 病房空调 设计参数 PMV—PPD指标 hospital, ward air conditioning, design parameters, PMV-PPD index
  • 相关文献

参考文献2

二级参考文献3

  • 1钱以明.高层建筑空调与节能[M].上海:同济大学出版社,1995..
  • 2[1]Mumma S A.Designing dedicated outdoor air systems[J].ASHRAE Journal,2001,(5):28-31.
  • 3[2]Dieckmann J,Kurt W R,Brodrick J.Dedicated outdoor air systems[J].ASHRAE Journal,2003,(3):58-59.

共引文献13