期刊文献+

放射治疗用新型定位杆的研制

Development of new-type locating rod for radiotherapy
下载PDF
导出
摘要 目的:研制一种安装简便、稳定可靠的放射治疗用定位杆。方法:该定位杆由联杆、钳型卡扣和卡扣收放装置组成。联杆长度为530_0^(+3)mm。联杆两端安装有两点承压式钳型卡扣,一端是固定的,另一端顺着滑行槽滑行。以偏心轮推动滑行卡扣收放2个卡口间距,并辅以回位弹簧提高卡扣滑行的顺应性。结果:该定位杆安装、操作简便,可适用的床板宽度为530_0^(+3)mm;定位杆锁紧后以手力推动无侧滑,如施以侧向牵拉力20 kgf(1 kgf=9.8 N),杆侧向位移≤1 mm。结论:该新型定位杆性能优良,能满足临床的使用要求。 Objective To develop a new type of locating rod with easy installation and high reliability for radiotherapy.Methods The locating rod was composed of a joining beam, two clamping buckles and buckle holders. The joining beam had the length being 530_0^(+3)mm One of the buckles was put at one end of the beam, and the other slided along a stool. An eccentric wheel drove the sliding buckle to determine the space between two buckles, and a returning spring was involved in to enhance the compliance of the sliding buckle. Results The rod gained easy installation and operation, and was compatible with the bed board with the width of 530_0^(+3)mm.There was no sideslip occurred after locking the rod, and the sideslip shift was not more than 1 mm in case of 20 kgf (1 kgf=9.8 N)lateral traction. Conclusion The rod has high performances and meets clinical requirements.
出处 《医疗卫生装备》 CAS 2017年第3期35-37,42,共4页 Chinese Medical Equipment Journal
基金 上海市科委产学研项目(11DZ1922002)
关键词 定位杆 放射治疗 卡扣 肿瘤治疗 体位固定 locating rod radiotherapy buckle oncotherapy postural immobilization
  • 相关文献

参考文献1

二级参考文献4

  • 1殷蔚伯,余子豪,徐国镇,等.肿瘤放射治疗学[M].4版.北京:中国协和医科大学出版社,2011:257-260.
  • 2爱德华·海普林,卡洛斯·佩雷兹,路德·布莱迪.放射肿瘤学原理和实践[M].朱广迎,李晔熊,夏廷毅,等译.5版.天津:天津科技翻译出版社,2012:203-204,331-354.
  • 3张玉龙,李萍.塑料专用料品种与性能[M].北京:化学工业出版社,2010:105-108.
  • 4张玉龙,孙敏.塑料品种与性能手册[M].2版.北京:化学工业出版社,2015:236-244.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部