摘要
结合《高规》错层结构的设计要求,提出了对规范没有明确规定的一般框架错层结构的设计要求,并通过一工程实例加以验证分析,提出应从概念化设计角度对这类结构及其构件进行重点设计,同时给出了可以采取的抗震构造措施。
Combined with technical specification for concrete structures of tall building, the design calculating method is presented on staggered frame structure which there have been few code rules on this topic.Based on a practical engineering example, the analysis result shows that conceptual design should be put in the first place.In addition, several seismic strengthening measures were presented to reference the practical engineering.
出处
《江苏建筑》
2017年第1期66-68,共3页
Jiangsu Construction
关键词
错层框架结构
抗震结构体系
抗震构造措施
概念设计
staggered frame structure
seismic structural system
details of seismic design
conceptual design