摘要 基于FLAC^(3D)软件,通过对比分析工程实测数据、数值仿真和规范方法结果,研究引水系统回填混凝土标号改变对钢衬变形和围岩内水压力分担率的影响。结果表明,现行规范在计算钢衬环向应力时,未考虑混凝土垫层,可能导致计算应力值偏差,进而影响围岩内水压力分担率;垫层混凝土标号由C15增加到C25,虽可减小钢衬的径向位移和环向拉应力,提高围岩内水压力分担率,但效果不显著。 Based on software FLAC3D, monitoring data are compared with the results of numerical simulation and specification method. And then this paper analyzes the influence of backfill concrete mark of diversion system on the deformation of steel lining and sharing ratio of internal pressure in surrounding rock. The results show that because the concrete cushion is ignored in the method of the recommended specification, the circumferential tensile stress is larger than the value by numerical simulation and it has impact on the sharing ratio of internal pressure in bedrock; the circumferential tensile stress and radical displacement decreased with the increase of cushion concrete mark from C15 to C25, but the effect is not obvious.
出处 《水电能源科学》 北大核心 2017年第4期139-141,共3页 Water Resources and Power
基金 国网新源控股有限公司科研项目(JXKJ-2015-03)
关键词 抽水蓄能电站 混凝土垫层 围岩内水压力分担率 规范方法 数值仿真 pumped-storage power station concrete cushion sharing ratio of internal pressure in bedrock specification method numerical simulation