期刊文献+

荧光编码微球的制备研究进展 被引量:2

Progress in the Preparation of Fluorescence-Encoded Microspheres
下载PDF
导出
摘要 悬浮芯片技术是近年来兴起的高通量生物检测技术,在生命科学研究及临床诊断等领域具有广泛应用。作为悬浮芯片技术的检测载体,荧光编码微球的研究已取得一系列进展。首先对悬浮芯片技术的检测原理及应用进行简单介绍,重点对荧光编码微球的制备方法进行总结,包括有机溶剂溶胀法、层-层自组装法、包埋法、微流控技术、膜乳化法等,最后对荧光编码微球未来的发展趋势进行探讨。 Suspension array is a promising platform for multiplex analyses with broad applications in science research and clinical diagnosis. As one of the key components for the suspension array, fluorescence-encoded microspheres have received much attention and a lot of achievements have been made. In this review, the analysis pattern and applications of suspension array were introduced, and recent advances in the fluorescence- encoded microspheres were summarized according to the classification of preparation methods including swelling method, layer-by-layer (LBL) self-assembly, embedding in microspheres, microfluidic techniques and membrane emulsification. Current challenges and future directions of fluorescence-encoded microspheres were also outlined.
出处 《中国生物医学工程学报》 CAS CSCD 北大核心 2017年第2期219-227,共9页 Chinese Journal of Biomedical Engineering
基金 国家自然科学基金(81471771) 江西省自然科学基金(20161BAB215196)
关键词 悬浮芯片 微球 荧光编码 量子点 suspension array microspheres fluorescence-encoding quantum dots
  • 相关文献

参考文献3

二级参考文献76

  • 1何英,陆学东.液相芯片技术及其临床应用[J].国际检验医学杂志,2006,27(12):1107-1108. 被引量:14
  • 2杨洋,汤华.液相芯片技术在检验医学和生物医学中的应用[J].中国生物化学与分子生物学报,2007,23(4):256-261. 被引量:32
  • 3Biagini R,Sammons D, Smith J, et al. Comparison of a multiplexed fluorescent covalent microsphere immunoassay and an enzyme-linked immunosorbent assay for measurement of human immunoglobulin G antibodies to anthrax toxins. Clin Diagn Lab Immunol, 2004, 11 : 50-55.
  • 4Luminex Corporation. http ://www. luminexcorp. com/support/proto- cols/protein. html.
  • 5Bellisario R,Colinas R, Pass K. Simultaneous measurement of anti- bodies to three HIV-1 antigens in newborn dried blood-spot speci- mens using a multiplexed microsphere-based immunoassay. Early Hum,2001,64(12) :21-25.
  • 6Pickering J,Martins T, Greer R,et al. A multiplexed fluorescent mi- crosphere immunoassay for antibodies to pneumocoecal capsular pol- ysaccharides. Am J Clin Pathol,2002 ,117 :589-596.
  • 7Whaley M, Rose C, Martinez J, et al. luterlaboratory comparison of three multiplexed bead-based immunoassays for measuring serum an- tibodies to pneumococcal polysaccharides. Clinical and Vaeine Im- munology,2010,17 (5) :862-869.
  • 8De-Jager W ,Te-Vehhuis H ,Prakken B, et al. Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells. Clin Diagn Lab Immunol, 2003,10 ( 1 ) : 133-139.
  • 9Morgan E, Varro R, Sepulveda H, et al. CytometrlC bead array: a multiplexed assay platform with applications in various areas of biolo- gy. Clin Immunol,2004 ,110 (3) :252-266.
  • 10Johannisson A, Jonasson R, Dernfalk J, et al. Simultaneous detection of porcine proinflammatory cytokines using multiplex flow cytometry by the xMAP technology. Cytometry A ,2006,69 (5) :391-395.

共引文献12