摘要
针对某钢厂精炼炉负荷进行电能质量治理,采用动态无功补偿装置(SVC),重点介绍了SVC装置参数设计思路,对SVC装置投入后的电能质量效果进行分析,提出后期改善方案。
SVC was adopted to control the power quality of ladle furnace in a steel plant. The design concept of the SVC parameters is mainly introduced. The power quality after application of SVC was analyzed and improvement program was put forward.
出处
《冶金动力》
2017年第5期1-3,共3页
Metallurgical Power
关键词
精炼炉
SVC
电压波动
ladle furnace
SVC