钢-混凝土组合结构基础隔震的振动台实验分析

Experimental study on shaking table of base isolation for steel-concrete composite structures
下载PDF
导出
摘要 文章主要研究基础隔震技术对于钢-混凝土组合结构的影响,即在不增加结构竖向刚度的情况下,在结构的基础与上部结构之间设置隔震层,通过隔震支座的耗能使得地震波的能量被消耗,从而达到降低结构加速度的效果,而且由于上部结构和基础部分可以相对移动,增加了结构的自振周期,避免产生共振。通过振动台实验对比,验证了基础隔震对于钢-混凝土组合结构的有效性以及优越性。 In this paper, the effect of the base isolation technology on the steel-concrete composite structure is studied, which is, without increasing the vertical stiffness of the structure, the isolation layer is arranged between the foundation and the superstructure. As the energy of seismic wave is consumed by the isolation bearing, the effect of reducing the acceleration of the structure will be achieved. What's more, because the upper structure and the base part can be moved relatively, the structure of the natural vibration period is increased and the resonance is avoided. By comparison of shaking table test, the validity and superiority of base isolation for steel-concrete composite structure are verified.
出处 《江苏科技信息》 2017年第9期49-51,共3页 Jiangsu Science and Technology Information
关键词 基础隔震 振动台 隔震效果 橡胶隔震支座 base isolation shaking table isolation effect rubber isolation bearings
  • 相关文献

参考文献2

二级参考文献14

  • 1刘伟庆,王曙光,林勇.宿迁市人防指挥大楼隔震设计方法研究[J].建筑结构学报,2005,26(2):81-86. 被引量:39
  • 2黄海生,王柏生.基础隔震建筑非线性动力响应的时程计算方法[J].振动与冲击,2005,24(3):50-52. 被引量:12
  • 3徐忠根,周福霖.我国首栋橡胶垫隔震住宅楼动力分析[J].世界地震工程,1996,12(1):38-42. 被引量:42
  • 4中国工程建设标准化协会.CECS126:2001.叠层橡胶支座隔震技术规程[S].2001.
  • 5中华人民共和国国家标准.建筑抗震设计规范(GB50011—2010)[M].北京:中国建筑工业出版社,2010.
  • 6周华明.土木工程结构试验与检测[M].南京:东南大学出版社,2002.
  • 7北村春幸.基于性能设计的建筑振动解析[M].裴星洙,廖红建,译.西安:西安交通大学出版社,2004.
  • 8日本建筑学会.刘文光译.2006.隔震结构设计[M].北京:地震出版社.
  • 9CB50011-2001建筑抗震设计规范[S].2008版.北京:中国建筑工业出版社,2008.G.
  • 10B50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.