期刊文献+

In-situ analysis of retained austenite transformation in high-performance micro-alloyed TRIP steel 被引量:2

In-situ analysis of retained austenite transformation in high-performance micro-alloyed TRIP steel
原文传递
导出
摘要 Microstructures and mechanical properties of Ti-V micro-alloyed TRIP( transformation-induced plasticity) steel with different compositions were investigated by tensile test,scanning electron microscopy( SEM),transmission electron microscopy( TEM),X-ray diffraction( XRD) and thermodynamic calculation( TC). The results indicated that the steel exhibited high ultimate tensile strength( 1 079MPa),sufficient ductility( 28%) and the highest product of strength and ductility( 30 212 MPa·%) heat treated after intercritical annealing at 800℃ for 3 min and bainitic annealing at 430 ℃ for 5 min. In addition,the change of volume fraction of retained austenite( VF-RA) versus tensile strain was measured using in-situ analysis by X-ray stress apparatus and micro-electronic universal testing machine. It was concluded that a-value could be used to evaluate the stability of retained austenite( S-RA) in the investigated Ti-V micro-alloyed TRIP steel. The smaller a-value indicated the higher stability of retained austenite( S-RA) and the higher mechanical properties of Ti-V micro-alloyed TRIP steel. Microstructures and mechanical properties of Ti-V micro-alloyed TRIP( transformation-induced plasticity) steel with different compositions were investigated by tensile test,scanning electron microscopy( SEM),transmission electron microscopy( TEM),X-ray diffraction( XRD) and thermodynamic calculation( TC). The results indicated that the steel exhibited high ultimate tensile strength( 1 079MPa),sufficient ductility( 28%) and the highest product of strength and ductility( 30 212 MPa·%) heat treated after intercritical annealing at 800℃ for 3 min and bainitic annealing at 430 ℃ for 5 min. In addition,the change of volume fraction of retained austenite( VF-RA) versus tensile strain was measured using in-situ analysis by X-ray stress apparatus and micro-electronic universal testing machine. It was concluded that a-value could be used to evaluate the stability of retained austenite( S-RA) in the investigated Ti-V micro-alloyed TRIP steel. The smaller a-value indicated the higher stability of retained austenite( S-RA) and the higher mechanical properties of Ti-V micro-alloyed TRIP steel.
出处 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2017年第3期313-320,共8页
基金 supported by the Shanghai Municipal Science and Technology Commission(Grant No.15DZ2260300,15DZ2260301) Shanghai Municipal Natural Science Foundation(17ZR1410400)
关键词 Ti-V micro-alloyed TRIP steel Retained austenite stability In-situ analysis Microstructure Ti-V micro-alloyed TRIP steel Retained austenite stability In-situ analysis Microstructure
  • 相关文献

同被引文献5

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部