期刊文献+

铜离子荧光探针的研究进展 被引量:5

Research Progress in Fluorescent Probes for Copper Ion Sensor
下载PDF
导出
摘要 高选择性、超灵敏性铜离子荧光探针的设计和开发,在环境检测、食品安全及人体内微量铜元素探测等领域具有重要意义。本文根据荧光分子探针对铜离子的识别机制和化学结构特点,从罗丹明、香豆素、芘基团、萘酰亚胺、氟硼吡咯及其他荧光基团等发色团出发,综述了近年来铜离子荧光探针的研究进展。参考文献27篇。 The design of high selectivity and sensitivity copper ion fluorescent probes are important in environmental monitoring, food safety and detection of trace copper ions in life. Based on the recogni- tion mechanism and chemical structure in copper ion fluorescence probe, the relative research progress in recent years was summarized and introduced from their chromophore structurers, such as rhodamine, coumarin, pyrene, naphthalimide, BODIPYs and other fluorophores with 27 references.
出处 《合成化学》 CAS CSCD 2017年第4期360-368,共9页 Chinese Journal of Synthetic Chemistry
基金 国家自然科学基金资助项目(51673118) 辽宁省高等学校杰出青年学者成长计划(LJQ2014014)
关键词 铜离子 荧光探针 催化 荧光增强 荧光淬灭 综述 copper ion fluorescent probe catalysis fluorescence enhancement fluorescence quench- ing review
  • 相关文献

参考文献7

二级参考文献66

  • 1赵同丰,赵德丰,于华云,程侣柏.1,8-萘酰亚胺类荧光材料的进展[J].染料工业,1997,34(1):8-15. 被引量:17
  • 2Gaggelli E, Kozlowski H, Valensin D; et. al. Copper Homeostasis and Neurodegenerative Disorders (Alzheimer's, Prion, and Parkinson's Diseases and Amyotrophic Lateral Sclerosis) [J].Chem. Rev. 2006,106(6):1995-2044.
  • 3Chunwei Yu, Jun Zhang, Jinhua Li; et. al. Fluorescent probe for copper (II) ion based on a rhodamine spirolactame derivative, and its application to fluorescent imaging in living cells [J]. Microchim. Acta, 2011, 174(3-4): 247-255.
  • 4Kun Dai, Baofian Xu, Jingwen Chen; A rhodamine-based "off-on" col- orimetric and fluorescent ehemosensor for Cu(Ⅱ) in aqueous and non-aque- ous Media [J] .J. fluoresc. 2014, 24: 1129-1136.
  • 5Li-hua Jin and Chang-soo Han Ultrasensitive and selective fluorimetric detection of copper ions using thiosulfate-involved quantum dots[J]. Anal. Chem., 2014, 86 (15): 7209 - 7213.
  • 6Yao Jianlei, Zhang Kui, Zhu Houjuan, et. al. Efficient ratiometric fluores- cence probe based on dual-emission quantum dots hybrid for on-site deter- mination of cooper ions[J].Anal. Chem. 2013, 85: 6461-6468.
  • 7Zhijun Chen, Limin Wang, Gang Zou, et. al. Highly selective fluores- cence turn-on chemosensor based on naphthalimide derivatives for detec- tion ofcopper(Ⅱ) ions Spectrochim[J].Acta Part A: 2013, 105: 57-61.
  • 8C. Satriano, G. T. Sfrazzetto, M. E. amato et. al. A ratiometric naph- thalimide sensor for live cell imaging of copper(Ⅰ) [J].Chem. Commun., 2013, 49, 5565-5567.
  • 9Shan Zhang, Tao Yu, Mingtai Sun; et. al. Highly sensitive and selective fluorescence detection of copper(Ⅱ) ion base donmulti-ligand metal chela- tion[J].Talanta 2014 126: 185-190.
  • 10M. H. Lee, H. J. Kim, S. ; et. al. Metal ion induced FRET off- on in tren/dansyl-appended rhodamine[J] .Org. Lett. ,2008, 10: 213-216.

共引文献26

同被引文献21

引证文献5

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部