摘要
铅酸电池在传统弹药引信中被大量使用。随着弹药功能的拓展,引信工作时间和过载加大,某些传统电池设计会引发产品故障,需要认真进行分析解决。本文就某弹药引信用铅酸电池故障进行分析,以期提供相关参考。
The lead-acid battery is widely used in conventional ammunition fuze. With the expansion of ammunition function, the working time and overload of fuze are increased .Some traditional battery design will lead to product failure, this need careful analysis and solution. In this paper, an ammunition fuze lead-acid battery failure analysis, with a view to provide relevant reference.
出处
《现代制造技术与装备》
2017年第3期119-121,共3页
Modern Manufacturing Technology and Equipment
关键词
引信
铅酸电池
放电试验
fuze, lead-acid battery, discharge test