激光传感器光轴垂直度误差标定方法 被引量:8

Calibration Method for Optical Axis Perpendicular Error of Laser Sensor
原文传递
导出
摘要 针对高精度复合式测量机中的激光传感器进行了高精度的标定,提出了利用已知底角的双斜面标定块和正弦定理标定光轴垂直度误差偏角的方法,分析了影响标定精度的因素。该方法避免了传感器光轴与工作台不垂直引入的各个方向的误差,可有效地提高该传感器的测量精度,为更高精度的多传感器复合测量提供了基础。 The high precision calibration of laser sensors in high-precision composite measuring machines is done. The calibration method of the optical axis perpendicular error angle by using the calibration block with double slopes with known base angles and the sine theorem is proposed. This method can avoid the errors from various directions caused by the non-perpendicular orientation between the optical axis of sensors and the worktable, which can effectively improve the measurement accuracy of this sensor and provide a basis for muhisensor duplex measurement with higher accuracy.
出处 《中国激光》 EI CAS CSCD 北大核心 2017年第4期218-227,共10页 Chinese Journal of Lasers
基金 国家重大科学仪器设备开发专项(2013YQ17053903)
关键词 传感器 垂直度误差标定 拟合平面斜率 光轴 高精度复合式测量 sensors calibration of perpendicular error fitted plane slope optical axis high-precision complex measurement