期刊文献+

Spring tube braces for seismic isolation of buildings 被引量:2

Spring tube braces for seismic isolation of buildings
下载PDF
导出
摘要 Abstract: A new low-cost seismic isolation system based on spring tube bracings has been proposed and studied at the Structural and Earthquake Engineering Laboratory of Istanbul Technical University. Multiple compression-type springs are positioned in a special cylindrical tube to obtain a symmetrical response in tension and compression-type axial loading. An isolation floor, which consists of pin-ended steel columns and spring tube bracings, is constructed at the foundation level or any intermediate level of the building. An experimental campaign with three stages was completed to evaluate the capability of the system. First, the behavior of the spring tubes subjected to axial displacement reversals with varying frequencies was determined. In the second phase, the isolation floor was assessed in the quasi-static tests. Finally, a scaled 3D steel frame was tested on the shake table using actual acceleration records. The transmitted acceleration to the floor levels is greatly diminished because of the isolation story, which effects longer period and higher damping. There are no stability and self- centering problems in the isolation floor. Abstract: A new low-cost seismic isolation system based on spring tube bracings has been proposed and studied at the Structural and Earthquake Engineering Laboratory of Istanbul Technical University. Multiple compression-type springs are positioned in a special cylindrical tube to obtain a symmetrical response in tension and compression-type axial loading. An isolation floor, which consists of pin-ended steel columns and spring tube bracings, is constructed at the foundation level or any intermediate level of the building. An experimental campaign with three stages was completed to evaluate the capability of the system. First, the behavior of the spring tubes subjected to axial displacement reversals with varying frequencies was determined. In the second phase, the isolation floor was assessed in the quasi-static tests. Finally, a scaled 3D steel frame was tested on the shake table using actual acceleration records. The transmitted acceleration to the floor levels is greatly diminished because of the isolation story, which effects longer period and higher damping. There are no stability and self- centering problems in the isolation floor.
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期219-231,共13页 地震工程与工程振动(英文刊)
基金 Research Project 36997 of Istanbul Technical University Research Funds
关键词 seismic isolation spring tube base isolation low-cost isolation seismic isolation spring tube base isolation low-cost isolation
  • 相关文献

同被引文献5

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部