机械通气在急性重度有机磷农药中毒致呼吸衰竭中的应用 被引量:8

Application of mechanical ventilation in respiratory failure caused by acute severe organophosphorus pesticide poisoning
下载PDF
导出
摘要 目的探讨急性重度有机磷农药中毒合并呼吸衰竭时机械通气在救治中的作用。方法收集25例急性重度有机磷农药中毒并发呼吸衰竭患者的临床资料。在常规方法治疗的基础上,均加用机械通气救治,并对其效果进行回顾性分析。结果 25例急性重度有机磷农药中毒并发呼吸衰竭的患者经过机械通气及综合治疗后,成功22例,死亡3例,成功率为88%。结论在抢救急性重度有机磷农药中毒并发呼吸衰竭时,及时采用机械通气是救治成功的关键。 Objective To investigate the effect of mechanical ventilation in the treatment of acute severe organophosphorus pesticide poisoning combined with respiratory failure. Methods the clinical data of 25 patients with acute severe organophospho- rus pesticide poisoning complicated with respiratory failure were collected. On the basis of routine treatment, were treated with mechanical ventilation, and the result were analyzed retrospectively. Results the patients with respiratory failure in 25 cases of acute severe organophosphorus pesticide poisoning patients after mechanical ventilation and comprehensive treatment, 22 cases were successful, 3 cases of death, the success rate is 88%. Conclusion poisoning complicated with respiratory failure in the treatment of acute severe organophosphorus pesticide, timely use of mechanical ventilation treatment is the key to success.
作者 高明峰
出处 《当代临床医刊》 2017年第2期2985-2986,共2页 Journal of Contemporary Clinical Medicine
关键词 急性重度有机磷农药中毒 呼吸衰竭 呼吸机 机械通气 acute severe organophosphorus pesticide poisoning respiratory failure mechanical ventilation mechanical ventilation
  • 相关文献

参考文献5

二级参考文献37

  • 1郭晓革.呼吸机辅助治疗急性心肌梗死并发心源性休克的CCU护理体会[J].现代诊断与治疗,2012,23(12):2297-2298. 被引量:3
  • 2张建军,雷球英.急性有机磷中毒临床治疗方法的再认识[J].内科急危重症杂志,2005,11(2):85-86. 被引量:40
  • 3Japoni A, Vazin A, Davarpanah MA, et al. Ventilator-associated pneumonia in Iranian intensive care units [J]. J Infect Dev Ctries, 20ll, 5 (4) : 286-293.
  • 4Rello J, Ollendorf DA, Oster G, et al. Epidemiology and outcomes of ventilator-associated pneumonia in a large US database [ J ]. Chest, 2002, 122 (6) : 2115-2121.
  • 5Hess D, Burns E, Romagnoli D, et al. Weekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates [J]. Anesthesiology, 1995, 82 (4):903-911.
  • 6Craven DE, Counolly MG Jr, Liehtenberg DA, et al. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours [ J ]. N Engl J Med, 1982, 306 (25) : 1505-1509.
  • 7Fink JB, Krause SA, Barrett L, et al. Extending ventilator circuit change interval beyond 2 days reduces the likelihood of ventilator- associated pneumonia [J]. Chest, 1998, 113 (2) : 405-411.
  • 8Long MN, Wickstrom G, Grimes A, et al. Prospective, randomized study of ventilator-associated pneumonia in patients with one versus three ventilator circuit changes per week [J]. Infect Control Hosp Epidemiol, 1996, 17 (1): 14-19.
  • 9Hess D, Bums E, Romagnoli D, et al. Weekly ventilator circuit changes: A strategy to reduce costs without affecting pneumonia rates [J]. Anesthesiology, 1995, 82 (4): 903-911.
  • 10Kollef MH, Shapiro SD, Fraser V J, et al. Mechanical ventilation with or without 7-day circuit changes: A randomized controlled trial [J]. Ann Intern Med, 1995, 123 (3): 168-174.

共引文献24

同被引文献72

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部