期刊文献+

北京市地埋管地源热泵项目应用效果评价分析 被引量:3

APPLICATION EFFECT EVALUATION OF GROUND-COUPLED GEOTHERMAL PUMPING PROJECTS IN BEIJING
下载PDF
导出
摘要 通过对27个北京市地埋管地源热泵项目应用数据的监测调查,从系统性能、地温变化、节能效益、环保效益和节能成本等方面进行统计分析,并应用主成分分析法和数据包络分析法对项目的效率进行综合评价,得出效率相对有效的项目17个,相对无效的项目10个,并分析无效项目的参数改进方向。最后提出地埋管地源热泵发展的4点建议:1)增加财政补贴可有效提高项目的投入产出效率;2)项目参数设计的合理性和运维管理的科学性是决定项目效率的根本因素;3)加强长期监测才能对地源热泵技术对环境影响程度有更准确的判断;4)优化项目投入产出效率是地埋管地源热泵项目普遍应用需要解决的重要问题。 This paper,based on application data of 27 ground-coupled geothermal pumping projects in Beijing,analyzes their system function,geothermal change,power-saving profits,environmental protection and energy-saving cost,and uses PCA and DEA to evaluate their efficiency,17 relatively efficient and 10 not efficient. Parameters improvement is given for the ten projects. This paper presents suggestions for ground-coupled geothermal pump projects on raising financial subsidy to increase input/output efficiency, setting rational parameters and keeping a well maintenance management which is key to efficiency, boosting a long-standing monitoring helpful for a better understanding of the impact of geothermal pumping technology on environment,and optimizing input/output efficiency which is a key aspect in ground-coupled geothermal pumping projects.
作者 刘静 雷涯邻 杨淼 LIU Jing LEI Ya-lin YANG Miao(School of Humanities and Economic Management, China University of Geosciences, Beijing 100083, China Beijing Geothermal Research Institute, Beijing 100012, China)
出处 《资源与产业》 2017年第2期76-81,共6页 Resources & Industries
关键词 地埋管地源热泵 评价 主成分分析法 数据包络分析法 ground-coupled geothermal pumping evaluation PCA DEA
  • 相关文献

参考文献6

二级参考文献34

共引文献21

同被引文献28

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部