期刊文献+

Design Study of a Cable-based Gait Training Machine 被引量:5

Design Study of a Cable-based Gait Training Machine
原文传递
导出
摘要 This paper deals with a design approach of a gait training machine based on a quantitative gait analysis. The proposed training machine is composed of a body weight support device and a cable-driven parallel robot. This paper is focused on the cable-driven robot, which controls the pose of the lower limb through an orthosis placed on the patient's leg. The cable robot reproduces a normal gait movement through the motion of the orthosis. A motion capture system is used to perform the quantitative analysis of a normal gait, which will be used as an input to the inverse dynamic model of the cable robot. By means of an optimization algorithm, the optimal design parameters, which minimize the tensions in the cables, are determined. Two constraints are considered, i.e., a non-negative tension in the cables at all times, and a free cable/end-effector collision. Once the optimal solution is computed, a power analysis is carried out in order to size the robot actuators. The proposed approach can be easily extended for the design study of a similar type of cable robots. This paper deals with a design approach of a gait training machine based on a quantitative gait analysis. The proposed training machine is composed of a body weight support device and a cable-driven parallel robot. This paper is focused on the cable-driven robot, which controls the pose of the lower limb through an orthosis placed on the patient's leg. The cable robot reproduces a normal gait movement through the motion of the orthosis. A motion capture system is used to perform the quantitative analysis of a normal gait, which will be used as an input to the inverse dynamic model of the cable robot. By means of an optimization algorithm, the optimal design parameters, which minimize the tensions in the cables, are determined. Two constraints are considered, i.e., a non-negative tension in the cables at all times, and a free cable/end-effector collision. Once the optimal solution is computed, a power analysis is carried out in order to size the robot actuators. The proposed approach can be easily extended for the design study of a similar type of cable robots.
出处 《Journal of Bionic Engineering》 SCIE EI CSCD 2017年第2期232-244,共13页 仿生工程学报(英文版)
关键词 gait rehabilitation cable-driven robots body weight support system design optimization gait rehabilitation, cable-driven robots, body weight support system, design optimization
  • 相关文献

参考文献3

二级参考文献26

  • 1Kun Qian,Xudong Ma,Xianzhong Dai,Fang Fang Key Lab of Measurement and Control of Complex Systems of Engineering (Ministry of Education,China), Southeast University,Nanjing 210096,P.R.China.Robotic Etiquette:Socially Acceptable Navigation of Service Robots with Human Motion Pattern Learning and Prediction[J].Journal of Bionic Engineering,2010,7(2):150-160. 被引量:3
  • 2Glynn A, Fiddler H. The Physiotherapists Pocket Guide to Exercise: As-Sessment, Prescription and Training, Elsevier, Churchhill Livingstone, 2009.
  • 3Hoppenfeld S, Murthy V L. Treatment and Rehabilitation of Fractures, Lippincott Williams & Wilkins, Philadelphia, USA, 1999.
  • 4Goffer A. Gait-locomotor apparatus,[2006-12-26], Patent US 7153242, https:lldata.epo.org/gpi/EPI260201 B I-Gait- locomotor-apparatus.
  • 5Kawamoto H, Hayashi 1; Sakurai 1; Eguchi K, Sankai Y Development of single leg version of hal for hemiplegia. Proceedings of the 31st Annual International Conference of the IEEE Engineering ittMedicine and Biology Society, Minneapolis, Minnesota, USA, 2009, 5038-5043.
  • 6Seo K H, Lee J J. The development of two mobile gait rehabilitation systems, IEEE Transactions on Neural Sys?tems and Rehabilitation Engi- neering, 2009, 17, 156- I 66.
  • 7Bouri M, Gall B L, Clavel R. A new concept of parallel robot for rehabilitation and fitness: The lambda. Proceedings of the IEEE International Conference on Robotics and Biomimetics, GuiIin, China, 2009, 2503-2508.
  • 8Homma K, Fukuda 0, Sugawara J, Nagata);' Usuba M. A wiredriven leg rehabilitation system: Development of a 4-DOF experimental system. Proceedings of the Interna?tional Conference on Advanced Intelligent Mechatronics, Port Island, Japan, 2003,908-913.
  • 9Nikitczuk J, Weinberg B, Canavan PK, Mavroidis C. Active knee rehabilitation orthotic device with variable damping characteristics implemented via an electrorheological fluid. IEEEIASME Transactions on Mechatronics, 2010, 15, 952-960.
  • 10Kikuchi T, Oda K, Furusho J. Leg-robot for demonstration of spastic movements of brain-injured patients with compact magnetorheological fluid clutch. Advanced Robotics, 2010, 24,671-686.

共引文献11

同被引文献53

引证文献5

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部