摘要
目的:基于细胞计数板建立一种简单、快速使用免疫荧光显微镜观察B淋巴细胞吞噬卡介苗(BCG)现象的新方法,对即将进行流式细胞检测的样品进行质控,提高流式细胞术检测吞噬率的稳定性,同时为流式细胞仪检测吞噬率提供镜下依据。方法:B细胞与FITC标记的BCG共培养24 h后,PE anti-human CD19抗体直接标记细胞膜,应用细胞计数板在荧光显微镜下观察B细胞吞噬现象,流式细胞仪检测吞噬率。结果:应用细胞计数板在荧光镜下可观察到B细胞与BCG的荧光标记及B细胞与BCG共标记现象,证实B细胞可吞噬BCG,流式细胞仪检测结果显示吞噬率为13.9%。结论:应用细胞计数板在荧光镜下可观察B细胞吞噬现象,且操作简便快速,能对流式细胞检测的样品进行质控,并提供镜下依据。
Objective: To establish a simple and quick method to explore phagocytosis of B lymphocytes under immunofluores- cence microscopy based on cell counting chamber. By monitoring the sample quality before flow cytometry(FCM), the method could im- prove the stability of phagocytic rate detected by FCM. It could also offer image proof under fluorescence microscopy at the same time. Methods: After Raji B lymphocytes and FITC-stained BCG were incubated together for 24 hrs, B lymphocytes were labeled by PE an- ti-human CD19 antibody. Then we applied cell counting chamber to observe phagocytosis of B lymphocytes and flow cytometry to test phagocytic rate. Results: B lymphocytes and BCG could be single labeled respectively and double labeled,which was observed under flu- orescence microscope based on cell counting chamber. The phagocytic rate tested by flow cytometry was 13.9 %. Conclusions: Observ- ing phagocytosis of B lymphocytes using cell counting chamber under fluorescence microscopy might be a simple and quick method. It can be applied in monitoring the sample quality before flow cytometry, it could also offer proof under fluorescence microscopy.
作者
吴梦丽
周林甫
石晓丹
刘学武
史明
冯国栋
赵钢
WU Meng-li ZHOU Lin-fu SHI Xiao-dan LIU Xue-wu SHI Ming FENG Guo-dong ZHAO Gang(Department of Neurology, Xijing Hospital, Fouth Millitary Medical University, Xi'an, Shaanxi, 710032, China)
出处
《现代生物医学进展》
CAS
2017年第11期2037-2040,共4页
Progress in Modern Biomedicine
基金
国家自然科学基金项目(81371334)
关键词
细胞计数板
荧光显微镜
B细胞
卡介苗
Cell counting chamber
Immunofluorescence microscopy
B lymphocyte
BCG