期刊文献+

子结构隔震的巨型框架结构地震反应分析与振动台试验研究 被引量:3

Numerical analysis of seismic response and shaking table test of mega frame structure with isolated sub-structure
原文传递
导出
摘要 为考察基于子结构隔震的巨型框架结构的实际振动控制效果,对一巨型框架结构和采用子结构隔震的巨型框架结构进行数值分析和振动台试验。介绍了巨型框架结构原型,采用有限元方法对巨型框架结构和采用子结构隔震的巨型框架结构进行分析,研究子结构隔震技术对外部主框架和内部子框架的地震反应控制效果。介绍了缩尺模型结构及其试验方案,对其进行了模拟地震的振动台试验,测量和分析了主框架和子框架的地震反应。有限元分析和振动台试验结果表明:子框架隔震后,巨型框架结构的基本周期得到延长,但隔震结构前6阶振型的振动都是以子框架振动为主,而非隔震结构前6阶振型的振动都是以主框架的振动为主。子框架隔震后,主框架和子框架的地震反应都显著减小,位置较低的子框架2的地震反应及其隔震效果一般要比上部子框架3的大。隔震子框架的变形主要集中在隔震层上,但隔震层变形小于主、子框架间的隔震缝宽度。 In order to investigate the actual vibration control effect of the isolated sub-structure for the mega frame structure,numerical simulation and shaking table test of the( non-isolated) mega frame structure and the isolated mega frame structure with isolated sub-structure were performed. The prototype structure was introduced, then numerical analyses of the structures were carried out using finite element method,to study the seismic response control effect of the sub-structure isolation technique towards the main structure and the sub-structure. The model structure and its test scheme were introduced. Shaking table tests of the model structures were performed,the seismic responses of the main structure and the sub-structure were measured and analyzed. Analysis and test results indicate that the basic period of the mega frame structure with isolated sub-structure is prolonged. The first six modes of vibration of the mega frame structure with isolated sub-structure are mainly the sub-structure's vibration,while the first six modes of vibration of the non-isolated mega frame structure are mainly the main structure's vibration. With the sub-structure being isolated,the seismic responses of the main frame structure and the sub-structure are reduced evidently. The seismic responses and control effects of the lower second sub-structure are larger than the third sub-structure. Lateral deformations of the isolated sub-structures are concentrated on the isolation layers,but the displacement of the isolation layers are less than the width of the isolation joint.
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2017年第5期43-51,共9页 Journal of Building Structures
基金 国家自然科学基金项目(51578160) 福建省教育厅科技项目(JA15050) 福建省高校杰出青年科研人才计划(810104)
关键词 巨型框架结构 隔震子结构 地震反应分析 振动台试验 减震效果 mega frame structure isolated sub-structure seismic response analysis shaking table test vibration control effect
  • 相关文献

参考文献6

二级参考文献49

共引文献183

同被引文献17

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部