期刊文献+

板角约束混凝土双向板抗火性能试验研究 被引量:5

Fire test on two-way concrete slab under corner restraint
原文传递
导出
摘要 为研究混凝土双向简支板板角受平面外约束下的火灾行为,进行了恒载-升温条件下的火灾试验。采用无线测温技术和红外探测技术,获得了火灾下双向板沿板厚温度场分布、钢筋温度、板平面内外变形、裂缝以及板角平面外约束力变化,并与国内外相关试验进行对比分析。测试结果表明:自行设计无线测温设备测量精确度较高,且便于使用;红外探测技术能够实时记录板面裂缝发展。分析结果表明:当板角受平面外约束时,其裂缝模式及变形规律与四边简支板明显不同;且板角区域易出现弧形裂缝,板角约束程度对板角区域弧形裂缝分布与发展有显著影响。 In order to analyze the fire behavior of the two-way concrete slab with out-of-plane restraints on comers under constant loads, one fire test which includes the wireless temperature measurement and infrared detection was conducted to obtain the temperature field along the depth, the reinforcement temperature, the out-of-plane and in- plane deflection, crack and the corners' out-of-plane restraint reaction. The test results also were compared with the relevant tests at home and abroad. Results indicate that the wireless measurement could get high-accuracy results with easy use, and the infrared detection technology can have a real-time observation on the slabs' cracks. The cracking pattern and deflection of the slab with out-of-plane restraints on the comers is clearly different from those of the simply support slabs, and arc-shaped cracks easily occurred near to slabs' comers. The corners' restraint degree has a considerable effect on the arc-shaped crack distribution and development of the slabs' comers.
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2017年第5期125-132,共8页 Journal of Building Structures
基金 国家青年科学基金项目(51408594) 中国博士后科学基金特别项目(2016T90525) 江苏建筑节能与建造技术协同创新中心项目(SJXTQ1614)
关键词 钢筋混凝土双向板 板角约束 受火试验 无线技术 红外探测 抗火性能 two-way RC slab restraint comer fire test wireless technology infrared detection fire behavior
  • 相关文献

参考文献5

二级参考文献55

  • 1蒋首超,李国强,周宏宇,王琦.钢-混凝土组合楼盖抗火性能的试验研究[J].建筑结构学报,2004,25(3):45-50. 被引量:21
  • 2陈礼刚,董毓利,李晓东.RC三跨连续板受火后的破坏形态分析[J].哈尔滨工业大学学报,2004,36(10):1358-1360. 被引量:8
  • 3袁爱民,孙宝俊,董毓利,李延和,高立堂.无粘结预应力混凝土简支板火灾试验研究[J].工业建筑,2005,35(4):38-42. 被引量:12
  • 4Wood R H. Plastic and elastic design of slabs and plates [M]. London: Thames and Hudson, 1961:225-261
  • 5Kemp K O. Yield of a square reinforced concrete slab on simple supports, allowing for membrane forces [J]. The Structural Engineer, 1967, 45(7): 235-240
  • 6Sawczuk A, Winnicki L. Plastic behaviour of simply supporter reinforced concrete plates at moderately large deflections[J]. International Journal of Solids Structures, 1965, 1:97-111
  • 7Li Guoqiang, Guo Shixiong, Zhou Haosheng. Modeling of membrane action in floor slabs subjected to fire [J]. Engineering Structure, 2007, (29): 880-887
  • 8Bailey C G, Moore D B. The structural behaviour of steel frames with composite floor slabs subjected to fire, part 1: theory[J]. The Structural Engineer, 2000, 78(11): 19-27
  • 9Bailey C G, Moore D B. The structural behaviour of steel frames with composite floor slabs subjected to fire, part 2:design[J]. The Structural Engineer, 2000, 78( 11 ): 28-33
  • 10Usmani A S, Cameron N J K. Limit capacity of laterally restrained reinforced concrete floor slabs in fire [J]. Cement & Concrete Composites, 2004, 26(2): 127-140

共引文献72

同被引文献29

引证文献5

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部